Abstract

Electron cyclotron emission (ECE) measurements are an important component of the diagnostic suite on the Tokamak a Configuration Variable (TCV) [F. Hoffman , Plasma Phys. Controlled Fusion 36, B277 (1994)]. A recently installed, 24-channel dual-conversion heterodyne radiometer covering the radio frequency range 65-100 GHz and viewing from the low-field side (LFS) of the tokamak greatly enhances the system and, in combination with an existing radiometer viewing from the high-field side (HFS), allows simultaneous measurements of emission from the HFS and LFS. In addition, the new radiometer has multiple lines of sight that can receive the emission perpendicular to the toroidal magnetic field as well as with a finite k(parallel to) (wave vector parallel to magnetic field). Such flexibility allows the LFS radiometer to make standard measurements of thermal emission and nonstandard measurements of nonthermal, anisotropic emission. The toroidal line of sight allows access to overdense plasma via mode converted emission. The enhanced ECE diagnostic is described and examples of measurements made in various configurations are presented. (c) 2005 American Institute of Physics.