Transient stability results for Nb3Sn cable-in-conduit conductors
Transient stability experiments are carried out on a Nb3Sn cable-in-conduit conductor in the SULTAN test facility. A disturbance of variable duration is applied by a pulsed field, transverse to the conductor axis. The results show a high tolerance to large field transients even in the current sharing regime, well correlated with the extremely low coupling loss. Local disturbances, nonhomogeneous over the cable cross section, are also applied to investigate the ability to redistribute the current locally among strands.
Type
research article
Web of Science ID
WOS:000176908600111
Authors
Publication date
2002
Published in
Volume
12
Issue
1
Start page
512
End page
515