Performance evolution of Nb3Sn cable-in-conduit conductors under cyclic load
Two subsize, Nb3Sn cable-in-conduit conductors, are tested as short samples in the SULTAN test facility. Transverse load is applied by sweeping up and down the operating current in high background field. A serious performance loss of I, and n-factor is observed upon cyclic load, with a drop of the critical current, I-c, larger than 30%. The results are critically discussed and compared to similar findings from the literature. The impact of the cyclic load on the Nb3Sn CICC performance must be carefully evaluated in the magnet design.
Cite this item
Bruzzone, P., Fuchs, A. M., Stepanov, B., & Vecsey, G. (2002). Performance evolution of Nb3Sn cable-in-conduit conductors under cyclic load. IEEE Transactions on Applied Superconductivity, 12(1), 516–519. https://doi.org/10.1109/TASC.2002.1018456
Click Copy to copy the citation, or select the text manually.
WOS:000176908600112
2002
12
1
516
519
REVIEWED
EPFL