A Novel Digital Image Processing System for the Transient Liquid Crystal Technique applied for Heat Transfer and Film Cooling Measurements

This paper is dedicated to the transient liquid crystal technique measurements for multiple view access by using a novel digital recording and image processing system. The transient liquid crystal technique is widely used for heat transfer investigations in turbomachinery. It has been applied in our laboratory in several test facilities such as a linear cascade for external film cooling measurements or on a ribbed squared duct for internal cooling measurements. The data analysis as well as the measurement equipment is described, with a special focus on the newly developed computerized image processing system suitable to capture the liquid crystal signal.


Published in:
Proceedings of the TURBINE-2000 Symposium at Cesme
Year:
2000
Keywords:
Other identifiers:
Laboratories:


Note: The status of this file is: EPFL only