  4. Feedback stabilization of axisymmetric modes in the TCV tokamak using active coils inside and outside the vacuum vessel
 
research article

Feedback stabilization of axisymmetric modes in the TCV tokamak using active coils inside and outside the vacuum vessel

Hofmann, F.  
•
Dutch, M. J.
•
Favre, A.
Show more
1998
Nuclear Fusion

A new vertical position control system, including an internal active coil, has become operational on TCV. The new system has made it possible to stabilize plasmas with open loop growth rates up to 4400 s(-1), currents up to 1.0 MA and elongations up to 2.58. The closed loop stability of the new system has been analysed with a numerical model in which the plasma is assumed to be undeformable, and the power supply outputs are delayed with respect to their inputs. Model predictions agree with the main experimental results.

  • Details
  • Metrics
Type
research article
DOI
10.1088/0029-5515/38/3/306
Author(s)
Hofmann, F.  
Dutch, M. J.
Favre, A.
Martin, Y.  
Moret, J. M.  
Ward, D. J.
Date Issued

1998

Publisher

IOP Publishing Ltd

Published in
Nuclear Fusion
Volume

38

Issue

3

Start page

399

End page

408

Editorial or Peer reviewed

REVIEWED

Written at

EPFL

EPFL units
CRPP  
SPC  
Available on Infoscience
April 16, 2008
Use this identifier to reference this record
https://infoscience.epfl.ch/handle/20.500.14299/21522
Logo EPFL, École polytechnique fédérale de Lausanne
  • Contact
  • infoscience@epfl.ch

  • Follow us on Facebook
  • Follow us on Instagram
  • Follow us on LinkedIn
  • Follow us on X
  • Follow us on Youtube
AccessibilityLegal noticePrivacy policyCookie settingsEnd User AgreementGet helpFeedback

Infoscience is a service managed and provided by the Library and IT Services of EPFL. © EPFL, tous droits réservés