  4. High-speed photography of compressed human trabecular bone correlates whitening to microscopic damage
 
research article

High-speed photography of compressed human trabecular bone correlates whitening to microscopic damage

Thurner, P. J.
•
Erickson, B.  
•
Jungmann, R.
Show more
2007
Engineering Fracture Mechanics

Mechanical testing of trabecular bone is mainly motivated by the huge impact of osteoporosis in post-menopausal women and the aged in society in terms of social and health care costs. Trabecular bone loss and impairment of its mechanical properties reduce bone strength and increase fracture risk, especially in vertebrae. It is generally accepted that in addition to bone mineral density, microarchitecture and material properties of bone also play important roles for bone strength and fracture risk. In order to overcome the limitations of standard mechanical tests delivering merely integral information about complicated samples, experiments were designed for step-wise mechanical testing with concurrent imaging of trabecular and cortical bone. In this communication we present an approach for real-time imaging of trabecular bone during compression using high-speed photography and investigate the hypothesis whether the whitening of deformed trabeculae is due to microdamage. Experiments on human trabecular bone samples from a healthy male donor revealed that failure of such samples is highly localized in fracture bands. Moreover, strongly deformed trabeculae were seen to whiten, an effect similar to stress whitening in polymers. Scanning Electron Microscopy of the same regions of interest revealed that whitened trabeculae were strongly damaged by microscopic cracks and mostly failed in delamination. Higher resolution images uncovered mineralized collagen fibrils spanning the cracks. The whitening partially faded after unloading of the samples, presumably due to partial crack closure. Overall, high-speed photography enables microdamage detection in real-time during a mechanical test and provides a correlation to recorded stress strain curves. (C) 2006 Elsevier Ltd. All rights reserved.

  • Details
  • Metrics
Type
research article
DOI
10.1016/j.engfracmech.2006.05.024
Web of Science ID

WOS:000247488600009

Author(s)
Thurner, P. J.
Erickson, B.  
Jungmann, R.
Schriock, Z.
Weaver, J. C.
Fantner, G. E.  
Schitter, G.
Morse, D. E.
Hansma, P. K.
Date Issued

2007

Published in
Engineering Fracture Mechanics
Volume

74

Issue

12

Start page

1928

End page

1941

Note

1st International Conference on the Mechanics of Biomaterials and Tissues

DEC, 2005

HI

Editorial or Peer reviewed

REVIEWED

Written at

OTHER

EPFL units
LBNI  
Available on Infoscience
November 5, 2010
Use this identifier to reference this record
https://infoscience.epfl.ch/handle/20.500.14299/56735
Logo EPFL, École polytechnique fédérale de Lausanne
  • Contact
  • infoscience@epfl.ch

  • Follow us on Facebook
  • Follow us on Instagram
  • Follow us on LinkedIn
  • Follow us on X
  • Follow us on Youtube
AccessibilityLegal noticePrivacy policyCookie settingsEnd User AgreementGet helpFeedback

Infoscience is a service managed and provided by the Library and IT Services of EPFL. © EPFL, tous droits réservés