  4. Comparing daylighting performances assessment of building within scale models and test modules
 
conference paper

Comparing daylighting performances assessment of building within scale models and test modules

Thanachareonkit, A.
•
Andersen, Marilyne  
•
Scartezzini, J.-L.  
2003
Proceedings of CISBAT 2003: Innovation in building envelopes and environmental systems
CISBAT 2003: Innovation in building envelopes and environmental systems

Physical models are commonly used to assess daylighting performance of buildings using sky simulators for purpose of research as well as practice. Recent studies have pointed out the general tendency of scale model assessments to overestimate the performance, usually expressed through work plane illuminance and daylight factor profiles, when compared to the real buildings. The cause of the discrepancy between buildings and scale models is due to several sources of experimental errors, such as modelling of building details, mocking-up of surface reflectances and glazing transmittance, as well as photometer features. To analyse the main sources of errors, a comparison of a full scale test module designed for experimentation of daylighting systems and its 1:10 scale model, placed within identical outdoor daylighting conditions, was undertaken. Several physical parameters were studied in order to determine their impact on the daylighting performance assessment. These include the accurate mocking-up of surface reflectances, the scale model location, as well as the photometric sensor properties. The experimental study shows that large discrepancies can occur between the performance figures. They lead, on average, to a relative divergence of + 60 % to + 105 % in favor of the scale model for different points located in the side lit room. Some of these discrepancies were caused by slight differences in surface reflectances and photometer cosine responses. These discrepancies were reduced to a + 30 % to + 35 % relative divergence, by putting in the effort to carefully mock up the geometrical and photometrical features of the test module. This included a sound calibration of photometric sensors, whose cosine-response appeared at the end to be responsible for the remaining relative divergence observed between the daylighting performance figures.

  • Files
  • Details
  • Metrics
Loading...
Thumbnail Image
Name

06_2003_CISBAT ScaleModelAT.png

Access type

openaccess

Size

8.96 KB

Format

PNG

Checksum (MD5)

2a432f5cd9628dd5e7e46ea42aff06b7

Loading...
Thumbnail Image
Name

Comparing daylighting performance assessment of buildings.pdf

Access type

openaccess

Size

1.57 MB

Format

Adobe PDF

Checksum (MD5)

95899c34fb89a47558d41f24421fe3a2

Logo EPFL, École polytechnique fédérale de Lausanne
  • Contact
  • infoscience@epfl.ch

  • Follow us on Facebook
  • Follow us on Instagram
  • Follow us on LinkedIn
  • Follow us on X
  • Follow us on Youtube
AccessibilityLegal noticePrivacy policyCookie settingsEnd User AgreementGet helpFeedback

Infoscience is a service managed and provided by the Library and IT Services of EPFL. © EPFL, tous droits réservés