  4. Design and modelling of a tubular dielectric elastomer actuator with constrained radial displacement as a cardiac assist device
 
research article

Design and modelling of a tubular dielectric elastomer actuator with constrained radial displacement as a cardiac assist device

Martinez, T.
•
Chavanne, J.
•
Walter, A.
Show more
October 1, 2021
Smart Materials And Structures

In this paper, we propose an improvement of a dielectric elastomer actuator (DEA) based augmented aorta. The actuator is a multi-layered tubular DEA subject to the internal pressure of the blood. When activated in synchronisation with the heart, the DEA supplies energy and limits the load on the left ventricle. The improvement consists in implementing a constraint on the radial displacement of the actuator. This addition allows to increase the electromechanical stability of the device by avoiding snap-through of the material leading to irreversible breakdown. By increasing the stability of the device, it allows to reach higher activation voltages and thus, a higher energy. In order to help the design of this new actuator, we have developed an analytical model of the inflation of a tubular DEA. In addition to previous works, the new model takes into account the multi-layered structure of the device as well as the constraint on the radial displacement to obtain accurate characteristics of the DEA. After validation with specially design experiments, the modelling is used to study the influence of the radial limitation value on the performances of the DEA.

  • Details
  • Metrics
Type
research article
DOI
10.1088/1361-665X/ac1fa8
Web of Science ID

WOS:000694428800001

Author(s)
Martinez, T.
Chavanne, J.
Walter, A.
Civet, Y.
Perriard, Y.  
Date Issued

2021-10-01

Publisher

IOP PUBLISHING LTD

Published in
Smart Materials And Structures
Volume

30

Issue

10

Article Number

105024

Subjects

Instruments & Instrumentation

•

Materials Science, Multidisciplinary

•

Materials Science

•

dielectric elastomer actuator

•

analytical modelling

•

augmented aorta

•

electromechanical instability

•

deformation

•

elasticity

Editorial or Peer reviewed

REVIEWED

Written at

EPFL

EPFL units
LAI  
CAM  
Available on Infoscience
September 25, 2021
Use this identifier to reference this record
https://infoscience.epfl.ch/handle/20.500.14299/181613
Logo EPFL, École polytechnique fédérale de Lausanne
  • Contact
  • infoscience@epfl.ch

  • Follow us on Facebook
  • Follow us on Instagram
  • Follow us on LinkedIn
  • Follow us on X
  • Follow us on Youtube
AccessibilityLegal noticePrivacy policyCookie settingsEnd User AgreementGet helpFeedback

Infoscience is a service managed and provided by the Library and IT Services of EPFL. © EPFL, tous droits réservés