Optical Monitoring of Water Side Permeation in Thin Film Encapsulation
The stability of long-term microfabricated implants is hindered by the presence of multiple water diffusion paths within artificially patterned thin-film encapsulations. Side permeation, defined as infiltration of molecules through the lateral surface of the thin structure, becomes increasingly critical with the trend of developing high-density and miniaturized neural electrodes. However, current permeability measurement methods do not account for side permeation accurately nor quantitatively. Here, a novel optical, magnesium (Mg)-based method is proposed to quantify the side water transmission rate (SWTR) through thin film encapsulation and validate the approach using micrometric polyimide (PI) and polyimide-silicon carbide (PI-SiC) multilayers. Through computed digital grayscale images collected with corroding Mg film microcells coated with the thin encapsulation, side and surface WTRs are quantified. A 4.5-fold ratio between side and surface permeation is observed, highlighting the crucial role of the PI-PI interface in lateral diffusion. Universal guidelines for the design of flexible, hermetic neural interfaces are proposed. Increasing encapsulation's width (interelectrode spacing), creating stronger interfacial interactions, and integrating high-barrier interlayers such as SiC significantly enhance the lateral hermeticity.|This study introduces a magnesium-based optical technique to quantify water permeation in thin film encapsulation, which becomes crucial as devices miniaturize. It highlights that design rules, robust interfacial interactions, and the use of high-barrier materials like silicon carbide significantly enhance the encapsulation's barrier effectiveness. This offers a novel approach to improving the durability of thin film coatings. image
Advanced Materials - 2024 - Wu - Optical Monitoring of Water Side Permeation in Thin Film Encapsulation.pdf
publisher
openaccess
CC BY
9.7 MB
Adobe PDF
2f00fd4bd493cfe5a4470023961b67b6