Repository logo

Infoscience

  • English
  • French
Log In
Logo EPFL, École polytechnique fédérale de Lausanne

Infoscience

  • English
  • French
Log In
  1. Home
  2. Academic and Research Output
  3. Journal articles
  4. Geometrical deployment for braided stent
 
research article

Geometrical deployment for braided stent

Bouillot, Pierre  
•
Brina, Olivier
•
Ouared, Rafik
Show more
2016
Medical Image Analysis

The prediction of flow diverter stent (FDS) implantation for the treatment of intracranial aneurysms (IAs) is being increasingly required for hemodynamic simulations and procedural planning. In this paper, a deployment model was developed based on geometrical properties of braided stents. The proposed mathematical description is first applied on idealized toroidal vessels demonstrating the stent shortening in curved vessels. It is subsequently generalized to patient specific vasculature predicting the position of the filaments along with the length and local porosity of the stent. In parallel, in-vitro and in-vivo FDS deployments were measured by contrast-enhanced cone beam CT (CBCT) in idealized and patient-specific geometries. These measurements showed a very good qualitative and quantitative agreement with the virtual deployments and provided experimental validations of the underlying geometrical assumptions. In particular, they highlighted the importance of the stent radius assessment in the accuracy of the deployment prediction. Thanks to its low computational cost, the proposed model is potentially implementable in clinical practice providing critical information for patient safety and treatment outcome assessment. (C) 2016 Elsevier B.V. All rights reserved.

  • Details
  • Metrics
Type
research article
DOI
10.1016/j.media.2016.01.006
Web of Science ID

WOS:000373546800007

Author(s)
Bouillot, Pierre  
Brina, Olivier
Ouared, Rafik
Yilmaz, Hasan
Farhat, Mohamed  
Erceg, Gorislav
Lovblad, Karl-Olof
Vargas, Maria Isabel
Kulcsar, Zsolt
Pereira, Vitor Mendes
Date Issued

2016

Publisher

Elsevier

Published in
Medical Image Analysis
Volume

30

Start page

85

End page

94

Subjects

Flow diverter stent

•

Braided stent

•

Virtual deployment

•

Geometrical model

•

Intracranial aneurysm

Note

FNS

Editorial or Peer reviewed

REVIEWED

Written at

EPFL

EPFL units
LMH  
Available on Infoscience
July 19, 2016
Use this identifier to reference this record
https://infoscience.epfl.ch/handle/20.500.14299/127817
Logo EPFL, École polytechnique fédérale de Lausanne
  • Contact
  • infoscience@epfl.ch

  • Follow us on Facebook
  • Follow us on Instagram
  • Follow us on LinkedIn
  • Follow us on X
  • Follow us on Youtube
AccessibilityLegal noticePrivacy policyCookie settingsEnd User AgreementGet helpFeedback

Infoscience is a service managed and provided by the Library and IT Services of EPFL. © EPFL, tous droits réservés