Repository logo

Infoscience

  • English
  • French
Log In
Logo EPFL, École polytechnique fédérale de Lausanne

Infoscience

  • English
  • French
Log In
  1. Home
  2. Academic and Research Output
  3. Journal articles
  4. Gene Expression Measurements by Quantitative Real-time PCR Depends on Short Amplicons and a Proper Normalization
 
research article

Gene Expression Measurements by Quantitative Real-time PCR Depends on Short Amplicons and a Proper Normalization

Antonov, J.
•
Goldstein, D. R.  
•
Oberli, A.
Show more
2005
Laboratory Investigation

Quantitative reverse transcriptase real-time PCR (QRT-PCR) is a robust method to quantitate RNA abundance. The procedure is highly sensitive and reproducible as long as the initial RNA is intact. However, breaks in the RNA due to chemical or enzymatic cleavage may reduce the number of RNA molecules that contain intact amplicons. As a consequence, the number of molecules available for amplification decreases. We determined the relation between RNA fragmentation and threshold values (Ct values) in subsequent QRT-PCR for four genes in an experimental model of intact and partially hydrolyzed RNA derived from a cell line and we describe the relation between RNA integrity, amplicon size and Ct values in this biologically homogenous system. We demonstrate that degradation-related shifts of Ct values can be compensated by calculating delta Ct values between test genes and the mean values of several control genes. These delta Ct values are less sensitive to fragmentation of the RNA and are unaffected by varying amounts of input RNA. The feasibility of the procedure was demonstrated by comparing Ct values from a larger panel of genes in intact and in partially degraded RNA. We compared Ct values from intact RNA derived from well-preserved tumor material and from fragmented RNA derived from formalin-fixed, paraffin-embedded (FFPE) samples of the same tumors. We demonstrate that the relative abundance of gene expression can be based on FFPE material even when the amount of RNA in the sample and the extent of fragmentation are not known.

  • Details
  • Metrics
Type
research article
DOI
10.1038/labinvest.3700303
Author(s)
Antonov, J.
Goldstein, D. R.  
Oberli, A.
Baltzer, A.
Pirotta, M.
Fleischmann, A.
Altermatt, H. J.
Jaggi, R.
Date Issued

2005

Published in
Laboratory Investigation
Volume

85

Start page

1040

End page

1050

Editorial or Peer reviewed

REVIEWED

Written at

EPFL

EPFL units
STAT  
Available on Infoscience
April 21, 2006
Use this identifier to reference this record
https://infoscience.epfl.ch/handle/20.500.14299/229907
Logo EPFL, École polytechnique fédérale de Lausanne
  • Contact
  • infoscience@epfl.ch

  • Follow us on Facebook
  • Follow us on Instagram
  • Follow us on LinkedIn
  • Follow us on X
  • Follow us on Youtube
AccessibilityLegal noticePrivacy policyCookie settingsEnd User AgreementGet helpFeedback

Infoscience is a service managed and provided by the Library and IT Services of EPFL. © EPFL, tous droits réservés