Lightning Currents Flowing in the Soil and Entering a Test Power Distribution Line Via Its Grounding

Schoene, J.
•
A. Uman, M.
•
A. Rakov, V.
Show more
2009
IEEE Transactions on Power Delivery

Current from nearby rocket-triggered lightning that flowed through the soil and into an unenergized test power distribution line was studied based on experimental data acquired in 2003 at the International Center for Lightning Research and Testing in Florida. The 15-pole, three-phase line was 812 m long, was equipped with four arrester stations, at poles 2, 6, 10, and 14, and was terminated in its characteristic impedance at poles I and 15. The neutral conductor of the line was grounded at each arrester station and at both line terminations. Measurements suggest that a significant fraction of the lightning current injected into the earth a distance of 11 in from pole 15 entered the line through the grounding system of pole 15. The peak value of the microsecond-scale return stroke current entering the line through the pole 15 line ground was 7% of the peak value of the return stroke current injected into the earth. The peak value of the millisecond-scale triggered lightning initial stage current and the millisecond-scale return-stroke and initial-stage charge transfer to the line through the pole 15 line ground was between 12% and 19% of the lightning peak current/charge transfer, indicating that the percentage values for the injected peak currents are dependent on the current waveshape: for microsecond-scale return stroke currents, possibly due to electromagnetic coupling effects, a smaller fraction of the current peak enters the line compared to millisecond-scale initial stage currents. In the latter case, any influence of electromagnetic coupling to the line on ground currents is expected to be negligible.

  • Details
  • Metrics
Type
research article
DOI
10.1109/TPWRD.2009.2014031
Web of Science ID

WOS:000267765100015

Author(s)
Schoene, J.
A. Uman, M.
A. Rakov, V.
Jerauld, J.
Rambo, K. J.
Jordan, D. M.
Schnetzer, G. H.
Paolone, M.  
Nucci, C.A.
Petrache, E.  
Show more
Date Issued

2009

Published in
IEEE Transactions on Power Delivery
Volume

24

Issue

3

Start page

1095

End page

1103

Subjects

Current measurements

•

electromagnetic coupling

•

grounding electrodes

•

grounds

•

lightning protection

•

power distribution lines

•

rocket-triggered lightning

•

Multiple Arresters

•

Induced Voltages

•

Division

•

Strikes

•

Surges

Editorial or Peer reviewed

REVIEWED

Written at

EPFL

EPFL units
LRE  
SCI-STI-FR  
DESL  
Available on Infoscience
August 31, 2009
Use this identifier to reference this record
https://infoscience.epfl.ch/handle/20.500.14299/42268
Logo EPFL, École polytechnique fédérale de Lausanne
  • Contact
  • infoscience@epfl.ch

  • Follow us on Facebook
  • Follow us on Instagram
  • Follow us on LinkedIn
  • Follow us on X
  • Follow us on Youtube
AccessibilityLegal noticePrivacy policyCookie settingsEnd User AgreementGet helpFeedback

Infoscience is a service managed and provided by the Library and IT Services of EPFL. © EPFL, tous droits réservés