Electrical Property of Platinum Micro Heater for Thermal Analysis of Microfluidic Device
This paper shows thermal measurement and analysis of a microfluidic device integrated with local thin film heater. Thermal analysis was calculated by finite element modeling. Electrical property of the micro heater was calibrated in advance of the thermal analysis due to the difference from the bulk property of Pt. The thermal analysis results agreed well with experimental results. Our integrative approach suggests an importance of proper electrical measurement in micro heaters with Joule heating.
Cite this item
Ueno, R., Yesilköy, F., Brugger, J., & Kim, B. (2015). Electrical Property of Platinum Micro Heater for Thermal Analysis of Microfluidic Device. IEEJ Transactions on Sensors and Micromachines, 135(8), 338–342. https://doi.org/10.1541/ieejsmas.135.338
Click Copy to copy the citation, or select the text manually.
2015
135
8
338
342