Repository logo

Infoscience

  • English
  • French
Log In
Logo EPFL, École polytechnique fédérale de Lausanne

Infoscience

  • English
  • French
Log In
  1. Home
  2. Academic and Research Output
  3. Journal articles
  4. A modular low-complexity ECG delineation algorithm for real-time embedded systems
 
Loading...
Thumbnail Image
research article

A modular low-complexity ECG delineation algorithm for real-time embedded systems

Bote, Jose Manuel
•
Recas, Joaquin  
•
Rincon Vallejos, Francisco Javier  
Show more
March 1, 2018
Journal of Biomedical Informatics

This work presents a new modular and lowcomplexity algorithm for the delineation of the different ECG waves (QRS, P and T peaks, onsets and end). Involving a reduced number of operations per second and having a small memory footprint, this algorithm is intended to perform realtime delineation on resource-constrained embedded systems. The modular design allows the algorithm to automatically adjust the delineation quality in run time to a wide range of modes and sampling rates, from a Ultra-low power mode when no arrhythmia is detected, in which the ECG is sampled at low frequency, to a complete High-accuracy delineation mode in which the ECG is sampled at high frequency and all the ECG fiducial points are detected, in case of arrhythmia. The delineation algorithm has been adjusted using the QT database, providing very high sensitivity and positive predictivity, and validated with the MIT database. The errors in the delineation of all the fiducial points are below the tolerances given by the Common Standards for Electrocardiography (CSE) committee in the High-accuracy mode, except for the P wave onset, for which the algorithm is above the agreed tolerances by only a fraction of the sample duration. The computational load for the ultra-low-power 8-MHz TI MSP430 series microcontroller ranges from 0.2 to 8.5% according to the mode used.

  • Files
  • Details
  • Metrics
Loading...
Thumbnail Image
Name

IEEE_JBHI-2018-07858735.pdf

Type

Publisher's Version

Access type

openaccess

Size

1.19 MB

Format

Adobe PDF

Checksum (MD5)

67f2d1914e45bc9d421a935886ad63d6

Loading...
Thumbnail Image
Name

JBHI2017-07858735.pdf

Type

Postprint

Access type

openaccess

Size

1.64 MB

Format

Adobe PDF

Checksum (MD5)

fc1d59c48753219951b5d369da949d5e

Logo EPFL, École polytechnique fédérale de Lausanne
  • Contact
  • infoscience@epfl.ch

  • Follow us on Facebook
  • Follow us on Instagram
  • Follow us on LinkedIn
  • Follow us on X
  • Follow us on Youtube
AccessibilityLegal noticePrivacy policyCookie settingsEnd User AgreementGet helpFeedback

Infoscience is a service managed and provided by the Library and IT Services of EPFL. © EPFL, tous droits réservés