Repository logo

Infoscience

  • English
  • French
Log In
Logo EPFL, École polytechnique fédérale de Lausanne

Infoscience

  • English
  • French
Log In
  1. Home
  2. Academic and Research Output
  3. Conferences, Workshops, Symposiums, and Seminars
  4. Building Climate-based Daylighting Models Based On One-time Field Measurements
 
conference paper

Building Climate-based Daylighting Models Based On One-time Field Measurements

Quek, Geraldine  
•
Jakubiec, John Alstan
2019
Proceedings of Building Simulation 2019: 16th Conference of IBPSA
16th IBPSA Conference Building Simulation (BS 2019)

Calibrated climate-based lighting simulation models of buildings perform an essential role in post-occupancy evaluations (POE), such as annual frequency assessments of daylighting quality and visual discomfort. However, the role of lighting analysis is temporally limited by instantaneous measurements or limited in scale by requiring constant monitoring of occupied spaces with expensive sensors. Building calibrated models is thus challenging due to limited information, short durations of access, the concurrent presence of electric lighting and daylighting, and transient usage of dynamic shades of occupied spaces. In this paper, the authors present a calibration process to build annual daylighting and electric lighting simulation models based on one-time field measurements, exemplified through a dataset of 540 individual office desks across 10 office spaces. The authors calibrated lighting models to be reliable enough for assessing the relationship of annualized climate-based daylighting metrics (CBDMs) to participants long-term perceptions of lighting quality. The proposed process to build calibrated climate-based models for POE’s based on one-time field measurements at each building is validated through comparing measured and simulated illuminance data at every work desk and results are sufficiently positive with logarithmic relative RMSE values of 4.3% and 6.8% and relative RMSE values of 25.8% and 45.5% for horizontal and vertical illuminances respectively. Vertical illuminance was found to vary more with measured data due to the uncertainty of monitor screen luminances. This paper demonstrates that measured data through onetime visits can be utilized to build reliable calibrated lighting simulation models to integrate long-term annual lighting results in post-occupancy evaluations.

  • Files
  • Details
  • Metrics
Loading...
Thumbnail Image
Name

BS2019_210105.pdf

Type

Publisher's Version

Version

Published version

Access type

openaccess

License Condition

CC BY-NC-ND

Size

16.85 MB

Format

Adobe PDF

Checksum (MD5)

b18cc585bda754b11b52d5ef310c320a

Logo EPFL, École polytechnique fédérale de Lausanne
  • Contact
  • infoscience@epfl.ch

  • Follow us on Facebook
  • Follow us on Instagram
  • Follow us on LinkedIn
  • Follow us on X
  • Follow us on Youtube
AccessibilityLegal noticePrivacy policyCookie settingsEnd User AgreementGet helpFeedback

Infoscience is a service managed and provided by the Library and IT Services of EPFL. © EPFL, tous droits réservés