Proposed Panel Zone Model for Beam-To-Column Joints in Steel Moment Resisting Frames

Skiadopoulos, Andronikos  
•
Elkady, Ahmed Mohamed Ahmed  
•
Lignos, Dimitrios  
October 19, 2023
Proceedings of the 10th National Conference of Steel Structures
10th National Conference of Steel Structures

In capacity designed steel moment resisting frames (MRFs), beam-to-column joints (i.e., panel zones) are designed to remain elastic. To potentially exploit the beneficial aspects of the stable panel zone hysteretic response in shear, a robust panel zone model is required. To assess the available panel zone models in the literature, a database of more than 100 experiments was systematically assembled. Experimental evidence suggests that available models may overestimate the panel zone shear strength by 40%. Regarding the model utilised in Europe, the column flange contribution to panel zone shear strength is disregarded, if continuity plates are not present, thereby underestimating the panel zone shear strength by 20%, on average. Moreover, only one doubler plate (if two are needed) is considered in the panel zone strength calculation. This paper examines realistic shear stresses in various panel zone geometries based on continuum finite element (CFE) simulations validated with available experimental data. The parametric analysis results are then leveraged to develop a new panel zone shear strength model for the seismic design of steel MRFs. Comparisons of the proposed panel zone shear stiffness and strength reveal a noteworthy accuracy of less than 10% error and decreased variation compared to existing models. Complementary CFE analyses on panel zones with doubler plates revealed that these are effective withstanding the shear strains developed in the column web. Thus, the panel zone thickness to be used in the proposed panel zone strength model should include the column web and the doubler plate(s).

  • Files
  • Details
  • Metrics
Loading...
Thumbnail Image
Name

PAP_Σκιαδόπουλος1.pdf

Type

Postprint

Version

http://purl.org/coar/version/c_ab4af688f83e57aa

Access type

openaccess

License Condition

CC BY-NC-ND

Size

1.35 MB

Format

Adobe PDF

Checksum (MD5)

a161617f62b071097654cd04884bced6

Logo EPFL, École polytechnique fédérale de Lausanne
  • Contact
  • infoscience@epfl.ch

  • Follow us on Facebook
  • Follow us on Instagram
  • Follow us on LinkedIn
  • Follow us on X
  • Follow us on Youtube
AccessibilityLegal noticePrivacy policyCookie settingsEnd User AgreementGet helpFeedback

Infoscience is a service managed and provided by the Library and IT Services of EPFL. © EPFL, tous droits réservés