Repository logo

Infoscience

  • English
  • French
Log In
Logo EPFL, École polytechnique fédérale de Lausanne

Infoscience

  • English
  • French
Log In
  1. Home
  2. Academic and Research Output
  3. Conferences, Workshops, Symposiums, and Seminars
  4. Dead-Time Effects in Voltage Source Inverter Fed Multi-Phase AC Motor Drives and Their Compensation
 
conference paper

Dead-Time Effects in Voltage Source Inverter Fed Multi-Phase AC Motor Drives and Their Compensation

Jones, M.
•
Dujic, D.
•
Levi, E.
Show more
2009
EPE: 2009 13TH EUROPEAN CONFERENCE ON POWER ELECTRONICS AND APPLICATIONS, VOLS 1-9
Power Electronics and Applications, 2009. EPE '09. 13th European Conference on

Inverter dead-time effects have been investigated in detail in the past for three-phase drives supplied from a three-phase voltage source inverter (VSI). A similar study has never been conducted in conjunction with multi-phase (more than three phases) drives, supplied from multi-phase VSIs. Regardless of the type of ac machine and its number of phases, the power supply of the drive is typically a two-level VSI, which requires a method of PWM for its operation. If a multi-phase machine is with sinusoidal field distribution, the PWM technique must generate sinusoidal harmonic-free output voltages in order to avoid appearance of low-order stator current harmonics. Recently a great deal of research has concentrated on PWM methods suitable for multi-phase VSIs. All of these PWM methods theoretically produce sinusoidal output voltages with no low order harmonics. As a consequence, rotor flux oriented control of multi-phase ac machines with sinusoidal MMF distribution can be theoretically realised by using only two current controllers in the synchronous reference frame. The paper shows that despite using a PWM method that does not produce low-order harmonics, in practice they do appear in the output voltage, and consequently currents, of the multi-phase VSI. Simulation studies show that low-order harmonics are generated as a result of inverter dead-time and that the effect of such harmonics on a five-phase ac machine can be significant due to the low machine impedance presented to these harmonics. Experimental results collected from a five-phase induction motor drive laboratory prototype are presented which reinforce this hypothesis. The paper further suggests a modified current control scheme that is able to fully compensate inverter dead-time effect and thus provide practically perfect sinusoidal currents. The proposed current control scheme is validated via simulation and experimentally.

  • Files
  • Details
  • Metrics
Loading...
Thumbnail Image
Name

2009_Con_Jones_Dead time effects in voltage source inverter fed multiphase AC motor drives and their compensation.pdf

Type

Publisher's Version

Version

http://purl.org/coar/version/c_970fb48d4fbd8a85

Access type

restricted

Size

358.42 KB

Format

Adobe PDF

Checksum (MD5)

2ba62bf58981a9fae3bf54428f2d9b29

Logo EPFL, École polytechnique fédérale de Lausanne
  • Contact
  • infoscience@epfl.ch

  • Follow us on Facebook
  • Follow us on Instagram
  • Follow us on LinkedIn
  • Follow us on X
  • Follow us on Youtube
AccessibilityLegal noticePrivacy policyCookie settingsEnd User AgreementGet helpFeedback

Infoscience is a service managed and provided by the Library and IT Services of EPFL. © EPFL, tous droits réservés