  4. Adaptive "load-distributed" muscle coordination method for kinematically redundant musculoskeletal humanoid systems
 
research article

Adaptive "load-distributed" muscle coordination method for kinematically redundant musculoskeletal humanoid systems

Dong, Haiwei
•
Figueroa, Nadia
•
El Saddik, Abdulmotaleb
2015
Robotics and Autonomous Systems

Muscle force control of musculoskeletal humanoid systems has been studied for years in the motor control, biomechanics and robotics disciplines. However, the study of "load-distributed" muscle control has seldomly been contemplated. In this paper, we consider muscle force control as a problem of muscle coordination. We propose a general muscle coordination method for a system driven by agonist and antagonist muscles. In our method, a set of linear equations is derived by connecting the acceleration description in both joint and muscle space where the pseudo inverse solution to these equations provides an initial optimal muscle force distribution. Thereafter, we redistribute the forces throughout the muscles by deriving a gradient direction for muscle force. This allows the muscles to satisfy force constraints and generate a distribution of forces throughout all the muscles. Moreover, to ensure that our proposed method is adaptive to modeling errors, we have constructed an estimated system model, which is added to the system to represent the real plant. By updating the parameters of the estimated model based on prediction error, the estimated model approaches the real plant gradually in real-time. The overall proposed method is evaluated on a bending-stretching movement of a musculoskeletal arm. We used two models (arm with 6 and 10 muscles) to verify the method. The force distribution analysis verifies the "load-distribution" property of the computed muscle force. The efficiency comparison shows that the computational time does not increase significantly with the increase of muscle number. The tracking error statistics of the two models show the validity of the method. (C) 2014 Elsevier B.V. All rights reserved.

  • Details
  • Metrics
Type
research article
DOI
10.1016/j.robot.2014.10.020
Web of Science ID

WOS:000348881600005

Author(s)
Dong, Haiwei
Figueroa, Nadia
El Saddik, Abdulmotaleb
Date Issued

2015

Publisher

Elsevier

Published in
Robotics and Autonomous Systems
Volume

64

Start page

59

End page

69

Subjects

Tendon-driven system

•

Redundancy solution

•

Adaptive parameter updating

Editorial or Peer reviewed

REVIEWED

Written at

EPFL

EPFL units
IMT  
Available on Infoscience
May 29, 2015
Use this identifier to reference this record
https://infoscience.epfl.ch/handle/20.500.14299/114684
Logo EPFL, École polytechnique fédérale de Lausanne
  • Contact
  • infoscience@epfl.ch

  • Follow us on Facebook
  • Follow us on Instagram
  • Follow us on LinkedIn
  • Follow us on X
  • Follow us on Youtube
AccessibilityLegal noticePrivacy policyCookie settingsEnd User AgreementGet helpFeedback

Infoscience is a service managed and provided by the Library and IT Services of EPFL. © EPFL, tous droits réservés