  4. Full-field measurement of micromotion around a cementless femoral stem using micro-CT imaging and radiopaque markers
 
research article

Full-field measurement of micromotion around a cementless femoral stem using micro-CT imaging and radiopaque markers

Malfroy Camine, V.  
•
Rüdiger, H.A.
•
Pioletti, D.P.  
Show more
2016
Journal of Biomechanics

A good primary stability of cementless femoral stems is essential for the long-term success of total hip arthroplasty. Experimental measurement of implant micromotion with linear variable differential transformers is commonly used to assess implant primary stability in pre-clinical testing. But these measurements are often limited to a few distinct points at the interface. New techniques based on micro-computed tomography (micro-CT) have recently been introduced, such as Digital Volume Correlation (DVC) or markers-based approaches. DVC is however limited to measurement around non-metallic implants due to metal-induced imaging artifacts, and markers-based techniques are confined to a small portion of the implant. In this paper, we present a technique based on micro-CT imaging and radiopaque markers to provide the first full-field micromotion measurement at the entire bone–implant interface of a cementless femoral stem implanted in a cadaveric femur. Micromotion was measured during compression and torsion. Over 300 simultaneous measurement points were obtained. Micromotion amplitude ranged from 0 to 24 µm in compression and from 0 to 49 µm in torsion. Peak micromotion was distal in compression and proximal in torsion. The technique bias was 5.1 µm and its repeatability standard deviation was 4 µm. The method was thus highly reliable and compared well with results obtained with linear variable differential transformers (LVDTs) reported in the literature. These results indicate that this micro-CT based technique is perfectly relevant to observe local variations in primary stability around metallic implants. Possible applications include pre-clinical testing of implants and validation of patient-specific models for pre-operative planning.

  • Files
  • Details
  • Metrics
Loading...
Thumbnail Image
Name

Malfroy Camine et al. - Full-field measurement of micromotion around a cem.pdf

Type

Preprint

Version

http://purl.org/coar/version/c_71e4c1898caa6e32

Access type

openaccess

Size

669.96 KB

Format

Adobe PDF

Checksum (MD5)

838e7a0728cbe203c2b0d7cc026427f9

Logo EPFL, École polytechnique fédérale de Lausanne
  • Contact
  • infoscience@epfl.ch

  • Follow us on Facebook
  • Follow us on Instagram
  • Follow us on LinkedIn
  • Follow us on X
  • Follow us on Youtube
AccessibilityLegal noticePrivacy policyCookie settingsEnd User AgreementGet helpFeedback

Infoscience is a service managed and provided by the Library and IT Services of EPFL. © EPFL, tous droits réservés