Repository logo

Infoscience

  • English
  • French
Log In
Logo EPFL, École polytechnique fédérale de Lausanne

Infoscience

  • English
  • French
Log In
  1. Home
  2. Academic and Research Output
  3. Journal articles
  4. Effects of hardware heterogeneity on the performance of SVM Alzheimer's disease classifier
 
research article

Effects of hardware heterogeneity on the performance of SVM Alzheimer's disease classifier

Abdulkadir, Ahmed
•
Mortamet, Bénédicte  
•
Krueger, Gunnar  
Show more
2011
Neuroimage

Fully automated machine learning methods based on structural magnetic resonance imaging data can assist radiologists in the diagnosis of Alzheimer's disease (AD). These algorithms require large data sets to learn the separation of subjects with and without AD. Training and test data may come from heterogeneous hardware settings which can potentially affect the performance of disease classification. A total of 518 MRI sessions from 226 healthy controls and 191 individuals with probable AD were used to systematically investigate the effect of different hardware (i.e. vendor, field strength, coil system) on the performance of support vector machine (SVM) classifiers. Data from the multicenter Alzheimer's Disease Neuroimaging Initiative (ADNI) were used in this study. We compared the change of the SVM decision value resulting from (a) changes in hardware against the effect of disease and (b) changes resulting simply from rescanning the same subject on the same machine. Maximum accuracy of 87% was obtained with a training set of all 417 subjects. Classifiers trained with 95 subjects in each diagnostic group and acquired with heterogeneous scanner settings had an empirical detection accuracy of 83.9 ± 2.2 % when tested on an independent set of the same size. These results mirror the accuracy reported in recent studies. Encouragingly, classifiers trained on images acquired with homogenous and heterogeneous hardware settings had equivalent cross validation performances. Two scans of the same subject acquired on the same machine had very similar decision values and were generally classified into the same group. Higher variation was introduced when two acquisitions of the same subject were performed on two scanners with different field strengths. The variation was unbiased and similar for both diagnostic groups. The findings of the study encourage the pooling of data from different sites to increase the number of training samples and thereby improving performance of disease classifiers. Although small, a change in hardware could lead to a change of the decision value and thus diagnostic grouping. Based on these results we recommend to report the level of diagnostic confidence when these methods are applied in a clinical setting involving different sets of hardware.

  • Details
  • Metrics
Type
research article
DOI
10.1016/j.neuroimage.2011.06.029
Author(s)
Abdulkadir, Ahmed
Mortamet, Bénédicte  
Krueger, Gunnar  
Vemuri, Prashanti
Jack, Clifford
Kloeppel, Stefan
Date Issued

2011

Publisher

Elsevier

Published in
Neuroimage
Volume

58

Issue

3

Start page

785

End page

792

Subjects

Magnetic resonance imaging

•

Support vector machines

•

Alzheimer's disease

•

multi-site study

•

LTS5

Editorial or Peer reviewed

REVIEWED

Written at

EPFL

EPFL units
LTS5  
Available on Infoscience
March 18, 2011
Use this identifier to reference this record
https://infoscience.epfl.ch/handle/20.500.14299/65433
Logo EPFL, École polytechnique fédérale de Lausanne
  • Contact
  • infoscience@epfl.ch

  • Follow us on Facebook
  • Follow us on Instagram
  • Follow us on LinkedIn
  • Follow us on X
  • Follow us on Youtube
AccessibilityLegal noticePrivacy policyCookie settingsEnd User AgreementGet helpFeedback

Infoscience is a service managed and provided by the Library and IT Services of EPFL. © EPFL, tous droits réservés