Publication: Luminosity scans for beam diagnostics
Luminosity scans for beam diagnostics
cris.lastimport.scopus | 2024-08-03T08:18:39Z | |
cris.lastimport.wos | 2024-08-09T09:33:45Z | |
cris.legacyId | 261974 | |
cris.virtual.department | LPAP | |
cris.virtual.orcid | 0000-0002-3218-0048 | |
cris.virtual.parent-organization | IPHYS | |
cris.virtual.parent-organization | SB | |
cris.virtual.parent-organization | EPFL | |
cris.virtual.sciperId | 169663 | |
cris.virtual.unitId | 10658 | |
cris.virtual.unitManager | Seidel, Mike | |
cris.virtualsource.author-scopus | 776ef87e-a919-4841-a666-d346f7a7d9b6 | |
cris.virtualsource.department | 776ef87e-a919-4841-a666-d346f7a7d9b6 | |
cris.virtualsource.orcid | 776ef87e-a919-4841-a666-d346f7a7d9b6 | |
cris.virtualsource.parent-organization | 431f63b4-007a-4d4d-b7c3-34801f606541 | |
cris.virtualsource.parent-organization | 431f63b4-007a-4d4d-b7c3-34801f606541 | |
cris.virtualsource.parent-organization | 431f63b4-007a-4d4d-b7c3-34801f606541 | |
cris.virtualsource.parent-organization | 431f63b4-007a-4d4d-b7c3-34801f606541 | |
cris.virtualsource.rid | 776ef87e-a919-4841-a666-d346f7a7d9b6 | |
cris.virtualsource.sciperId | 776ef87e-a919-4841-a666-d346f7a7d9b6 | |
cris.virtualsource.unitId | 431f63b4-007a-4d4d-b7c3-34801f606541 | |
cris.virtualsource.unitManager | 431f63b4-007a-4d4d-b7c3-34801f606541 | |
datacite.rights | openaccess | |
dc.contributor.author | Hostettler, M. | |
dc.contributor.author | Fuchsberger, K. | |
dc.contributor.author | Papotti, G. | |
dc.contributor.author | Papaphilippou, Y. | |
dc.contributor.author | Pieloni, T. | |
dc.date.accessioned | 2018-12-13T15:58:33 | |
dc.date.available | 2018-12-13T15:58:33 | |
dc.date.created | 2018-12-13 | |
dc.date.issued | 2018-10-12 | |
dc.date.modified | 2024-10-18T10:20:04.664406Z | |
dc.description.abstract | A new type of fast luminosity separation scans ("emittance scans") was introduced at the CERN Large Hadron Collider (LHC) in 2015. The scans were performed systematically in every fill with full-intensity beams in physics production conditions at the interaction point (IP) of the compact muon solenoid (CMS) experiment. They provide both transverse emittance and closed orbit measurements at a bunch-by-bunch level. The precise measurement of beam-beam closed orbit differences allowed a direct, quantitative observation of long-range beam-beam PACMAN effects, which agrees well with numerical simulations from an improved version of the TRAIN code. | |
dc.description.notes | This is an open access article under the terms of the Creative Commons Attribution License | |
dc.description.sponsorship | LPAP | |
dc.identifier.doi | 10.1103/PhysRevAccelBeams.21.102801 | |
dc.identifier.isi | WOS:000447195000001 | |
dc.identifier.uri | ||
dc.relation | https://infoscience.epfl.ch/record/261974/files/PhysRevAccelBeams.21.102801.pdf | |
dc.relation.issn | 2469-9888 | |
dc.relation.journal | Physical Review Accelerators And Beams | |
dc.subject | Physics, Nuclear | |
dc.subject | Physics, Particles & Fields | |
dc.subject | Physics | |
dc.title | Luminosity scans for beam diagnostics | |
dc.type | text::journal::journal article::research article | |
dspace.entity.type | Publication | |
dspace.file.type | Publisher's version | |
dspace.legacy.oai-identifier | oai:infoscience.epfl.ch:261974 | |
epfl.curator.email | ||
epfl.lastmodified.email | ||
epfl.legacy.itemtype | Journal Articles | |
epfl.legacy.submissionform | ARTICLE | |
epfl.oai.currentset | SB | |
epfl.oai.currentset | OpenAIREv4 | |
epfl.oai.currentset | article | |
epfl.peerreviewed | REVIEWED | |
epfl.publication.version | ||
epfl.writtenAt | EPFL | |
oaire.citation.articlenumber | 102801 | |
oaire.citation.issue | 10 | |
oaire.citation.volume | 21 | |
oaire.licenseCondition | CC BY | |
oaire.version |