Leakage Flux Modelling in Magnetic Fluids Test Bench
The proposed paper discusses a new methodology to monitor the B-H curve of magnetic fluids, which have low relative permeability. The set-up consists of a magnetic circuit which encloses a sample. A first coil allows creating a magnetic field into the sample whereas a second one measures the flux density. A reluctance network taking into account the leakage flux is investigated in order to improve the result of a simple reluctance network. In fact, a comparison of the two reluctance networks is effectuated according to the Vibrating Sample Magnetometer measurement, which gives an error up to 80% for the simple reluctance network, while the relative error is equal to 20% with the new developed reluctance network presented in this paper.
WOS:000387100300123
2016
978-1-5090-2065-2
Piscataway, NJ, USA
6
IEEE ASME International Conference on Advanced Intelligent Mechatronics
757
62
REVIEWED
Event name | Event place | Event date |
Banff, AB, Canada | July 12-15, 2016 | |