  4. Fire protection systems for building floors made of pultruded GFRP profiles. Part 1: Experimental investigations
 
research article

Fire protection systems for building floors made of pultruded GFRP profiles. Part 1: Experimental investigations

Correia, J. R.
•
Branco, F. A.
•
Ferreira, J. G.
Show more
2010
Composites Part B

This paper presents results of experimental investigations on the behaviour of GFRP pultruded profiles exposed to fire, in order to study the viability of their structural use in floors of buildings, taking into account the fulfilment of fire resistance requirements. The feasibility and efficacy of using three different protective coatings/layers, often used to protect structural steel, and a water cooling system to provide fire protection to GFRP pultruded profiles were investigated. The experimental programme included dynamic mechanical analyses (DMA), thermogravimetric and differential scanning calorimetry (TGA/DSC) experiments and fire resistance tests on GFRP tubular loaded beams. The unprotected GFRP beam failed after about 38 min, the three different passive protection systems provided a fire resistance between 65-76 min and the water cooling system provided a fire resistance of at least 120 min. Failure occurred in the upper part of the beams, due to compression and shear stresses. Results of these experiments allowed defining the field of application of each investigated solution, according to building code requirements. © 2010 Elsevier Ltd. All rights reserved.

  • Details
  • Metrics
Type
research article
DOI
10.1016/j.compositesb.2010.09.018
Web of Science ID

WOS:000284925600006

Author(s)
Correia, J. R.
Branco, F. A.
Ferreira, J. G.
Bai, Y.  
Keller, T.  
Date Issued

2010

Publisher

Elsevier

Published in
Composites Part B
Volume

41

Issue

8

Start page

617

End page

629

Subjects

Building material

•

Construction work and architectural phenomena

•

Cooling tower

•

Differential scanning calorimetry

•

Engineering

•

Equipment

•

Experiment

•

Fire

•

Fire protection

•

Materials

•

Materials testing

•

Mechanics

•

Polymer

Editorial or Peer reviewed

REVIEWED

Written at

EPFL

EPFL units
CCLAB  
Available on Infoscience
January 10, 2011
Use this identifier to reference this record
https://infoscience.epfl.ch/handle/20.500.14299/62842
Logo EPFL, École polytechnique fédérale de Lausanne
  • Contact
  • infoscience@epfl.ch

  • Follow us on Facebook
  • Follow us on Instagram
  • Follow us on LinkedIn
  • Follow us on X
  • Follow us on Youtube
AccessibilityLegal noticePrivacy policyCookie settingsEnd User AgreementGet helpFeedback

Infoscience is a service managed and provided by the Library and IT Services of EPFL. © EPFL, tous droits réservés