  4. Simple and accurate way for estimating total and segmental arterial compliance: the pulse pressure method
 
research article

Simple and accurate way for estimating total and segmental arterial compliance: the pulse pressure method

Stergiopulos, N.  
•
Meister, J. J.  
•
Westerhof, N.
1994
Annals of biomedical engineering

We derived and tested a new, simple, and accurate method to estimate the compliance of the entire arterial tree and parts thereof. The method requires the measurements of pressure and flow and is based on fitting the pulse pressure (systolic minus diastolic pressure) predicted by the two-element windkessel model to the measured pulse pressure. We show that the two-element windkessel model accurately describes the modulus of the input impedance at low harmonics (0-4th) of the heart rate so that the gross features of the arterial pressure wave, including pulse pressure, are accounted for. The method was tested using a distributed nonlinear model of the human systemic arterial tree. Pressure and flow were calculated in the ascending aorta, thoracic aorta, common carotid, and iliac artery. In a linear version of the systemic model the estimated compliance was within 1% of the compliance at the first three locations. In the iliac artery an error of 7% was found. In a nonlinear version, we compared the estimates of compliance with the average compliance over the cardiac cycle and the compliance at the mean working pressure. At the first three locations we found the estimated and "actual" compliance to be within 12% of each other. In the iliac artery the error was larger. We also investigated an increase and decrease in heart rate, a decrease in wall elasticity and exercise conditions. In all cases the estimated total arterial compliance was within 10% of mean compliance. Thus, the errors result mainly from the nonlinearity of the arterial system. Segmental compliance can be obtained by subtraction of compliance determined at two locations.

  • Details
  • Metrics
Type
research article
DOI
10.1007/BF02368245
PubMed ID

7998684

Author(s)
Stergiopulos, N.  
Meister, J. J.  
Westerhof, N.
Date Issued

1994

Published in
Annals of biomedical engineering
Volume

22

Issue

4

Start page

392

End page

397

Subjects

Blood Pressure

•

Compliance

•

Linear Models

•

Models

•

Cardiovascular

•

Pulse

Editorial or Peer reviewed

REVIEWED

Written at

EPFL

EPFL units
LCB  
LHTC  
Available on Infoscience
December 16, 2010
Use this identifier to reference this record
https://infoscience.epfl.ch/handle/20.500.14299/62310
Logo EPFL, École polytechnique fédérale de Lausanne
  • Contact
  • infoscience@epfl.ch

  • Follow us on Facebook
  • Follow us on Instagram
  • Follow us on LinkedIn
  • Follow us on X
  • Follow us on Youtube
AccessibilityLegal noticePrivacy policyCookie settingsEnd User AgreementGet helpFeedback

Infoscience is a service managed and provided by the Library and IT Services of EPFL. © EPFL, tous droits réservés