  4. Prototyping Conventionally Wound High-Frequency Magnetic Sensors for ITER
 
research article

Prototyping Conventionally Wound High-Frequency Magnetic Sensors for ITER

Testa, D.  
•
Toussaint, M.
•
Chavan, R.  
Show more
2012
Fusion Science and Technology

The high-frequency (HF) magnetic sensors for ITER are currently based on a conventional, Mirnov-type, pick-up coil, with an effective area in the range 0.03<(NA)EFF[m2]<0.1; the sensor is required to provide measurements of magnetic instabilities with magnitude around |deltaB/BPOL|~10-4 in the 10kHz to 2MHz frequency range. The physical, mechanical and electrical properties of one representative ITER HF pick-up coil design have been analyzed with particular attention to the manufacturing and assembly process for the winding pack, as its integrity was found to be of concern when performing a coupled electro-magnetic, structural and thermal analysis of the sensor. Three different options for the guiding grooves in that design have been tested, using copper and tungsten for the winding pack, but none of them has been convincing enough due to the likelihood of breakages of the thin grooving and of the tungsten wire itself. Hence, alternative designs still based on a conventional Mirnov-type pick-up coil have been explored, and a non-conventional Mirnov-type pick-up coil was produced using direct laser-cutting of a stainless steel hollow tube, avoiding the difficulties encountered during the winding operations for the conventional Mirnov-type sensors. This process manufacturing appears to be acceptable for HF magnetic sensors of Mirnov-type design in ITER, and it is recommended for future prototyping studies, as the effective area of our first prototype (NA)EFF~0.01m2 was well below the ITER requirement. The electrical characteristics and the frequency response of all these prototypes were evaluated up to 8MHz, with the results in good agreement with model calculations. The conventional Mirnov-type prototypes behave as expected in terms of their main electrical properties, and should satisfy the present measurement performance requirements. Finally, a direct measurement of the effective area of these sensors has shown that the geometrical value is a sufficiently correct estimate of its actual value at low frequencies (<10kHz) when the winding pack closely follows the nominal shape of the coil itself.

  • Files
  • Details
  • Metrics
Loading...
Thumbnail Image
Name

1103902.pdf

Access type

openaccess

Size

1.82 MB

Format

Adobe PDF

Checksum (MD5)

96d2de6fa4713a82e152d2d1e79755e8

Logo EPFL, École polytechnique fédérale de Lausanne
  • Contact
  • infoscience@epfl.ch

  • Follow us on Facebook
  • Follow us on Instagram
  • Follow us on LinkedIn
  • Follow us on X
  • Follow us on Youtube
AccessibilityLegal noticePrivacy policyCookie settingsEnd User AgreementGet helpFeedback

Infoscience is a service managed and provided by the Library and IT Services of EPFL. © EPFL, tous droits réservés