  4. Testing an inverse modeling approach with gradient boosting regression for stroke volume estimation using patient thermodilution data
 
research article

Testing an inverse modeling approach with gradient boosting regression for stroke volume estimation using patient thermodilution data

Bikia, Vasiliki (Vicky)  
•
Adamopoulos, Dionysios
•
Roffi, Marco
Show more
March 18, 2025
Frontiers In Artificial Intelligence

Stroke volume (SV) is a major indicator of cardiovascular function, providing essential information about heart performance and blood flow adequacy. Accurate SV measurement is particularly important for assessing patients with heart failure, managing patients undergoing major surgeries, and delivering optimal care in critical settings. Traditional methods for estimating SV, such as thermodilution, are invasive and unsuitable for routine diagnostics. Non-invasive techniques, although safer and more accessible, often lack the precision and user-friendliness needed for continuous bedside monitoring. We developed a modified method for SV estimation that combines a validated 1-D model of the systemic circulation with machine learning. Our approach replaces the traditional optimization process developed in our previous work, with a regression method, utilizing an in silico-generated dataset of various hemodynamic profiles to create a gradient boosting regression-enabled SV estimator. This dataset accurately mimics the dynamic characteristics of the 1-D model, allowing for precise SV predictions without resource-intensive parameter adjustments. We evaluated our method against SV values derived from the gold standard thermodilution method in 24 patients. The results demonstrated that our approach provides a satisfactory agreement between the predicted and reference data, with a MAE of 16 mL, a normalized RMSE of 21%, a bias of -9.2 mL, and limits of agreement (LoA) of [-47, 28] mL. A correlation coefficient of r = 0.7 (p < 0.05) was reported, with the predicted SV slightly underestimated (68 +/- 23 mL) in comparison to the reference SV (77 +/- 26 mL). The significant reduction in computational time of our method for SV assessment should make it suitable for real-time clinical applications.

  • Files
  • Details
  • Metrics
Loading...
Thumbnail Image
Name

frai-2-1530453.pdf

Type

Main Document

Version

Published version

Access type

openaccess

License Condition

CC BY

Size

2.23 MB

Format

Adobe PDF

Checksum (MD5)

a460d373e7761799230a5aba335d34d4

Logo EPFL, École polytechnique fédérale de Lausanne
  • Contact
  • infoscience@epfl.ch

  • Follow us on Facebook
  • Follow us on Instagram
  • Follow us on LinkedIn
  • Follow us on X
  • Follow us on Youtube
AccessibilityLegal noticePrivacy policyCookie settingsEnd User AgreementGet helpFeedback

Infoscience is a service managed and provided by the Library and IT Services of EPFL. © EPFL, tous droits réservés