OBJECTIVE The authors developed a new, real-time interactive inverse planning approach, based on a fully convex framework, to be used for Gamma Knife radiosurgery.

METHODS The convex framework is based on the precomputation of a dictionary composed of the individual dose distributions of all possible shots, considering all their possible locations, sizes, and shapes inside the target volume. The convex problem is solved to determine the plan, i.e., which shots and with which weights, that will actually be used, considering a sparsity constraint on the shots to fulfill the constraints while minimizing the beam-on time. The system is called IntuitivePlan and allows data to be transferred from generated dose plans into the Gamma Knife treatment planning software for further dosimetry evaluation.

RESULTS The system has been very efficiently implemented, and an optimal plan is usually obtained in less than 1 to 2 minutes, depending on the complexity of the problem, on a desktop computer or in only a few minutes on a high-end laptop. Dosimetry data from 5 cases, 2 meningiomas and 3 vestibular schwannomas, were generated with IntuitivePlan. Results of evaluation of the dosimetry characteristics are very satisfactory and adequate in terms of conformity, selectivity, gradient, protection of organs at risk, and treatment time.

CONCLUSIONS The possibility of using optimal, interactive real-time inverse planning in conjunction with the Leksell Gamma Knife opens new perspectives in radiosurgery, especially considering the potential use of the full capabilities of the latest generations of the Leksell Gamma Knife. This approach gives new users the possibility of using the system for easier and quicker access to good-quality plans with a shorter technical training period and opens avenues for new planning strategies for expert users. The use of a convex optimization approach allows an optimal plan to be provided in a very short processing time. This way, innovative graphical user interfaces can be developed, allowing the user to interact directly with the planning system to graphically define the desired dose map and to modify on-the-fly the dose map by moving, in a very user-friendly manner, the isodose surfaces of an initial plan. Further independent quantitative prospective evaluation comparing inverse planned and forward planned cases is warranted to validate this novel and promising treatment planning approach.

  • Details
  • Metrics
Type
research article
DOI
10.3171/2018.7.GKS181572
Web of Science ID

WOS:000453374900017

Author(s)
Levivier, Marc
Carrillo, Rafael E.  
Charrier, Remi  
Martin, Andre
Thiran, Jean-Philippe  
Date Issued

2018-12-01

Publisher

AMER ASSOC NEUROLOGICAL SURGEONS

Published in
Journal Of Neurosurgery
Volume

129

Start page

111

End page

117

Subjects

Clinical Neurology

•

Surgery

•

Neurosciences & Neurology

•

gamma knife

•

stereotactic radiosurgery

•

inverse planning

•

dosimetry

•

convex optimization

•

conformity

•

gradient

Note

19th International Meeting of the Leksell-Gamma-Knife-Society (LGKS) on Next-Generation Gamma Knife Research, Dubai, U ARAB EMIRATES, Mar 04-08, 2018

Editorial or Peer reviewed

REVIEWED

Written at

EPFL

EPFL units
LTS2  
LTS5  
Available on Infoscience
December 28, 2018
Use this identifier to reference this record
https://infoscience.epfl.ch/handle/20.500.14299/153246
Logo EPFL, École polytechnique fédérale de Lausanne
  • Contact
  • infoscience@epfl.ch

  • Follow us on Facebook
  • Follow us on Instagram
  • Follow us on LinkedIn
  • Follow us on X
  • Follow us on Youtube
AccessibilityLegal noticePrivacy policyCookie settingsEnd User AgreementGet helpFeedback

Infoscience is a service managed and provided by the Library and IT Services of EPFL. © EPFL, tous droits réservés