Sensor Letters

A miniaturized circular vertical Hall device with 8 contacts was studied in terms of its sensitivity, biasing topologies and residual offset. The geometry accounts for about 30% lower sensitivity, but offers the possibility of biasing the whole device in all sampling phases, which proves better for residual offset.

  • Details
  • Metrics
Type
research article
DOI
10.1166/sl.2009.1083
Web of Science ID

WOS:000271193300028

Author(s)
Banjevic, M.  
Reymond, S.
Popovic, R. S.  
Date Issued

2009

Published in
Sensor Letters
Volume

7

Start page

325

End page

328

Subjects

Hall Device

•

Circular Vertical Hall Device

•

Sensitivity

•

Biasing Topology

•

Residual Offset

Editorial or Peer reviewed

REVIEWED

Written at

EPFL

EPFL units
LMIS3  
Available on Infoscience
November 30, 2010
Use this identifier to reference this record
https://infoscience.epfl.ch/handle/20.500.14299/59701
Logo EPFL, École polytechnique fédérale de Lausanne
  • Contact
  • infoscience@epfl.ch

  • Follow us on Facebook
  • Follow us on Instagram
  • Follow us on LinkedIn
  • Follow us on X
  • Follow us on Youtube
AccessibilityLegal noticePrivacy policyCookie settingsEnd User AgreementGet helpFeedback

Infoscience is a service managed and provided by the Library and IT Services of EPFL. © EPFL, tous droits réservés