Repository logo

Infoscience

  • English
  • French
Log In
Logo EPFL, École polytechnique fédérale de Lausanne

Infoscience

  • English
  • French
Log In
  1. Home
  2. Academic and Research Output
  3. Conferences, Workshops, Symposiums, and Seminars
  4. REWARD: Design, Optimization, and Evaluation of a Real-Time Relative-Energy Wearable R-Peak Detection Algorithm *
 
conference paper

REWARD: Design, Optimization, and Evaluation of a Real-Time Relative-Energy Wearable R-Peak Detection Algorithm *

Orlandic, Lara
•
De Giovanni, Elisabetta  
•
Arza, Adriana  
Show more
October 7, 2019
2019 41st Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)
2019 41st Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)

Wearable devices are an unobtrusive, cost-effective means of continuous ambulatory monitoring of chronic cardiovascular diseases. However, on these resource-constrained systems, electrocardiogram (ECG) processing algorithms must consume minimal power and memory, yet robustly provide accurate physiological information. This work presents REWARD, the Relative-Energy-based WeArable R-Peak Detection algorithm, which is a novel ECG R-peak detection mechanism based on a nonlinear filtering method called Relative-Energy (Rel-En). REWARD is designed and optimized for real-time execution on wearable systems. Then, this novel algorithm is compared against three state-of-the-art real-time R-peak detection algorithms in terms of accuracy, memory footprint, and energy consumption. The Physionet QT and NST Databases were employed to evaluate the algorithms' accuracy and robustness to noise, respectively. Then, a 32-bit ARM Cortex-M3-based microcontroller was used to measure the energy usage, computational burden, and memory footprint of the four algorithms. REWARD consumed at least 63% less energy and 32% less RAM than the other algorithms while obtaining comparable accuracy results. Therefore, REWARD would be a suitable choice of R-peak detection mechanism for wearable devices that perform more complex ECG analysis, whose algorithms require additional energy and memory resources.

  • Files
  • Details
  • Metrics
Loading...
Thumbnail Image
Name

REWARD_Relative-Energy-based WeArable R-Peak Detection.pdf

Type

Preprint

Version

http://purl.org/coar/version/c_71e4c1898caa6e32

Access type

openaccess

Size

494.39 KB

Format

Adobe PDF

Checksum (MD5)

fc796db50c7cc8e3945da0d3bbcae524

Loading...
Thumbnail Image
Name

REWARD_Relative-Energy-based WeArable R-Peak Detection final.pdf

Type

Publisher's Version

Version

http://purl.org/coar/version/c_970fb48d4fbd8a85

Access type

openaccess

Size

494.39 KB

Format

Adobe PDF

Checksum (MD5)

fc796db50c7cc8e3945da0d3bbcae524

Logo EPFL, École polytechnique fédérale de Lausanne
  • Contact
  • infoscience@epfl.ch

  • Follow us on Facebook
  • Follow us on Instagram
  • Follow us on LinkedIn
  • Follow us on X
  • Follow us on Youtube
AccessibilityLegal noticePrivacy policyCookie settingsEnd User AgreementGet helpFeedback

Infoscience is a service managed and provided by the Library and IT Services of EPFL. © EPFL, tous droits réservés