  4. Implementation of the "loaded implant" model in the rat using a miniaturized setup - description of the method and first results
 
research article

Implementation of the "loaded implant" model in the rat using a miniaturized setup - description of the method and first results

Wiskott, H. W. Anselm
•
Bonhote, Philippe
•
Cugnoni, Joel  
Show more
2012
Clinical Oral Implants Research

Objective To miniaturize the loaded implant model to permit its application to small rodents. In this model, two titanium implants are placed 8 mm apart with their heads protruding from the skin and are forced together by a dedicated actuator. To assess the effect of (i) the post-implantation healing period and the duration of stimulation and (ii) the intratissular strain level on the microtomographical bone parameters BV/TV, Tb.N., Tb.Th. and BIC. Materials and methods Implants, 1 x 8 mm, were machined, inserted into the tibiae of rats and activated. A total of 123 animals were used. In series 1, the implants were left to heal for 2/4 weeks and then loaded to generate intratissular strains of 1125 +/- 5% mu e for 4/8 weeks. Series 2 had their implants loaded to 750, 1500 and 2250 +/- 5% mu e, respectively. Results Bone to implant contact increased upon loading. In series 1, no difference was observed regarding the duration of healing or the stimulation period. In series 2, at 750 mu e, the bone parameters did not differ from baseline. At 1500 mu e, all four parameters increased. At 2250 mu e, three of four parameters decreased relative to 1500 mu e. Conclusions (i) The loaded implant model can be miniaturized to the millimeter range; (ii) in the present model, implant activation beyond 4 weeks did not affect the bone parameters; (iii) mechanical stimulation increased bone to implant contact by up to 20%; (iv) the results obtained are consistent with the concept of an anabolic effect from 750 to 1500 mu e and deleterious effects at strains in the 2250 mu e range; and (v) strains at 2250 mu e did not lead to implant dis-integration.

  • Details
  • Metrics
Type
research article
DOI
10.1111/j.1600-0501.2011.02349.x
Web of Science ID

WOS:000311402600005

Author(s)
Wiskott, H. W. Anselm
Bonhote, Philippe
Cugnoni, Joel  
Durual, Stephane
Zacchetti, Giovanna
Botsis, John  
Scherrer, Susanne S.
Ammann, Patrick
Date Issued

2012

Publisher

Wiley-Blackwell

Published in
Clinical Oral Implants Research
Volume

23

Issue

12

Start page

1352

End page

1359

Subjects

bone

•

loading

•

rat

•

strain

•

stress

•

tissue response

Editorial or Peer reviewed

REVIEWED

Written at

EPFL

EPFL units
LMAF  
Available on Infoscience
February 27, 2013
Use this identifier to reference this record
https://infoscience.epfl.ch/handle/20.500.14299/89197
Logo EPFL, École polytechnique fédérale de Lausanne
  • Contact
  • infoscience@epfl.ch

  • Follow us on Facebook
  • Follow us on Instagram
  • Follow us on LinkedIn
  • Follow us on X
  • Follow us on Youtube
AccessibilityLegal noticePrivacy policyCookie settingsEnd User AgreementGet helpFeedback

Infoscience is a service managed and provided by the Library and IT Services of EPFL. © EPFL, tous droits réservés