  4. Absolute depth-dose-rate measurements for an 192Ir HDR brachytherapy source in water using MOSFET detectors
 
research article

Absolute depth-dose-rate measurements for an 192Ir HDR brachytherapy source in water using MOSFET detectors

Zilio, V. O.
•
Joneja, O. P.
•
Popowski, Y.
Show more
2006
Medical Physics

Reported MOSFET measurements concern mostly external radiotherapy and in vivo dosimetry. In this paper, we apply the technique for absolute dosimetry in the context of HDR brachytherapy using an 192Ir source. Measured radial dose rate distributions in water for different planes perpendicular to the source axis are presented and special attention is paid to the calibration of the R and K type detectors, and to the determination of appropriate correction factors for the sensitivity variation with the increase of the threshold voltage and the energy dependence. The experimental results are compared with Monte Carlo simulated dose rate distributions. The experimental results show a good agreement with the Monte Carlo simulations: the discrepancy between experimental and Monte Carlo results being within 5% for 82% of the points and within 10% for 95% of the points. Moreover, all points except two are found to lie within the experimental uncertainties, confirming thereby the quality of the results obtained

  • Details
  • Metrics
Type
research article
DOI
10.1118/1.2198168
Web of Science ID

WOS:000238688500002

Author(s)
Zilio, V. O.
Joneja, O. P.
Popowski, Y.
Rosenfeld, A.
Chawla, R.  
Date Issued

2006

Publisher

AIP for American Assoc. Phys. Med

Published in
Medical Physics
Volume

33

Issue

6

Start page

1532

End page

9

Subjects

brachytherapy

•

dosimetry

•

iridium

•

Monte Carlo methods

•

MOSFET

Note

Lab. de Phys. des Reacteurs et de Comportement des Syst., Ecole Polytechnique Fed. de Lausanne, Lausanne, Switzerland

Editorial or Peer reviewed

REVIEWED

Written at

EPFL

EPFL units
LRS  
Available on Infoscience
September 17, 2010
Use this identifier to reference this record
https://infoscience.epfl.ch/handle/20.500.14299/53889
Logo EPFL, École polytechnique fédérale de Lausanne
  • Contact
  • infoscience@epfl.ch

  • Follow us on Facebook
  • Follow us on Instagram
  • Follow us on LinkedIn
  • Follow us on X
  • Follow us on Youtube
AccessibilityLegal noticePrivacy policyCookie settingsEnd User AgreementGet helpFeedback

Infoscience is a service managed and provided by the Library and IT Services of EPFL. © EPFL, tous droits réservés