Repository logo

Infoscience

  • English
  • French
Log In
Logo EPFL, École polytechnique fédérale de Lausanne

Infoscience

  • English
  • French
Log In
  1. Home
  2. Academic and Research Output
  3. Datasets and Code
  4. Wideband integrated bioaerosol sensor (WIBS) excited, fluorescent, and hyper-fluorescent particle number concentrations and normalized size distributions (dN/dlogDp) measured in the Swiss container during MOSAiC 2019/2020
 
dataset

Wideband integrated bioaerosol sensor (WIBS) excited, fluorescent, and hyper-fluorescent particle number concentrations and normalized size distributions (dN/dlogDp) measured in the Swiss container during MOSAiC 2019/2020

Beck, Ivo  
•
Moallemi, Alireza  
•
Rolo, Margarida
Show more
2023
Zenodo

These datasets contain the total particle number concentrations and normalized size distributions (dN/dlogDp) of excited, fluorescent, and hyper-fluorescent particles of sizes 0.5 to 20 μm (optical diameter). The normalized size distribution datasets are split into 20 size bins: 0.5 - 0.6 μm, 0.6 - 0.72 μm, 0.72 - 0.87 μm, 0.87 - 1.05 μm, 1.05 - 1.26 μm, 1.26 - 1.51 μm, 1.51 - 1.82 μm, 1.82 - 2.19 μm, 2.19 - 2.63 μm, 2.63 - 3.16 μm, 3.16 - 3.8 μm, 3.8 - 4.57 μm, 4.57 - 5.5 μm, 5.5 - 6.61 μm, 6.61 - 7.95 μm, 7.95 - 9.56 μm, 9.56 - 11.50 μm, 11.5 - 13.83 μm, 13.83- 16.63 μm and 16.63 - 20 μm. The data were measured by a WIBS-NEO (Wideband Integrated Bioaerosol Sensor, model New Electronics option) by droplet measurement techniques ltd. The data were processed using the IGOR WIBS toolkit V1.36 (DMT) and python version 3.9.7. These datasets have been averaged to 1 hour time resolution. The datasets were cleaned from local pollution sources by applying a pollution flag developed by Beck et al. (2022a,b), which is based on the rate of change in particle number concentration with 1 min time resolution. Data points with more than 10 polluted minutes within an hour were removed from the WIBS datasets. Time periods with zero filter measurements and time periods with unstable flow that affected number concentrations have been removed from the dataset. The WIBS measures the size, asymmetry and fluorescence of particles with an optical diameter of 0.5 – 20 µm. Detected particles are excited by two UV flashlamps at wavelengths of 280 and 370 nm and their emitted fluorescence is measured by two photomultipliers with bandwidths of 310 - 400 nm, and 420 - 650 nm. The WIBS counts excited particles at a maximum frequency of 125 Hz, which corresponds to a maximum concentration of 2.5*104 particles/L with a sample flow of 0.3 L/min. Excited particles were classified as fluorescent if their fluorescent intensity exceeded the background intensity by three standard deviations (3σ) and as hyper-fluorescent if the fluorescent intensity exceeded the background intensity by 9σ. Excited particles with a lower fluorescent intensity were considered to be non-fluorescent. The background fluorescence was determined by measuring the fluorescent signal in the measurement chamber in absence of particles. Background measurements were performed every 26 h. The combination of two excitation wavelengths and two detector wavebands allows the classification of fluorescent particles into seven types: A, B, C, AB, AC, BC, and ABC (Perring et al. (2015); Savage et al. (2017)). For further information about the instrumental setup, refer to Heutte et al. (2023).

  • Details
  • Metrics
Type
dataset
DOI
10.1594/pangaea.961065
Author(s)
Beck, Ivo  
Moallemi, Alireza  
Rolo, Margarida
Quéléver, Lauriane
Jokinen, Tuija
Laurila, Tiia
Schmale, Julia  
Date Issued

2023

Publisher

Zenodo

EPFL units
EERL  
RelationURL/DOI

IsSupplementTo

https://infoscience.epfl.ch/record/305961
Available on Infoscience
December 11, 2023
Use this identifier to reference this record
https://infoscience.epfl.ch/handle/20.500.14299/202584
Logo EPFL, École polytechnique fédérale de Lausanne
  • Contact
  • infoscience@epfl.ch

  • Follow us on Facebook
  • Follow us on Instagram
  • Follow us on LinkedIn
  • Follow us on X
  • Follow us on Youtube
AccessibilityLegal noticePrivacy policyCookie settingsEnd User AgreementGet helpFeedback

Infoscience is a service managed and provided by the Library and IT Services of EPFL. © EPFL, tous droits réservés