Nagib, H.Monkewitz, P.Mascotelli, L.Bellani, G.Talamelli, A.2020-09-242020-09-242020-09-242019-01-0110.1007/978-3-030-22196-6_31https://infoscience.epfl.ch/handle/20.500.14299/171870WOS:000567879900031Further examination of the pressure measurement uncertainties in determining the pressure gradient along the fully-developed section of CICLoPE, yields a Karman constant based on the centerline velocity of kappa(CL) = 0.43 +/- 0.06. More significantly, we conclude that the CICLoPE facility requires a more accurate pressure scanning method for determining dp/dx; e.g., using a Scanivalve connected to a single more accurate pressure transducer.Uncertainty Analysis of the Von Karman Constant for the Mean Centerline Velocity in CICLoPEtext::conference output::conference proceedings::conference paper