Karpushov, A. N.Abdrashitov, G. F.Averboukh, IIBosshard, P.Condrea, I.Duval, B. P.Ivanov, A. A.Kolmogorov, V. V.Mlynar, J.Perez, A.Shikhovtsev, I. V.Shukaev, A. N.Weisen, H.2008-04-162008-04-162008-04-16200310.1016/S0920-3796(03)00373-9https://infoscience.epfl.ch/handle/20.500.14299/21961WOS:000185617900139A diagnostic neutral beam injector (DNBI) [CRPP report LRP 710/01, CRPP-EPFL, 200 1; EPS Conf. Comr. Fusion Plasma Phys., 25A (2001) 365] has been installed on tokamak A configuration variable (TCV) [Plasma Phys. Control Fusion, 36 (1994) 13277; Plasma Phys. Control Fusion, 43 (200 1) A 16 1; Plasma Phys. Control Fusion, to be published] for the purpose of providing local measurements of plasma ion temperature, velocity and impurity density by Charge exchange recombination spectroscopy (CXRS) [EPS Conf. Contr. Fusion Plasma Phys., 25A (2001) 365]. The system recently underwent a technical upgrade, which allowed to increase the full neutral beam current density by a factor of two (from 0.5 to 1 A at 52 keV injection energy) and to extend the operational range of the diagnostic. This was achieved by means of a new, larger ion source, with an increased extraction area and corresponding enhancements of the power supplies. (C) 2003 Elsevier B.V. All rights reserved.Upgrade of the diagnostic neutral beam injector for the TCV tokamaktext::journal::journal article::research article