Dielectric measurements on high-Q ceramics in the microwave region

The postresonator method proposed by Hakki and Coleman for the measurement of dielectric properties of solids in the microwave region is reexamined. Based on the experiments performed around 10 GHz, the limitations of the method in loss determination for materials with tan delta < 5 x 10(-4) are outlined. Alternative techniques for studying high-Q materials are described. Loss measurements performed on well-prepared ceramics have been used to draw comparisons among these techniques. Some of the experimental findings are new and are reported for the first time.


Published in:
Journal of the American Ceramic Society, 80, 5, 1095-1100
Year:
1997
ISSN:
0002-7820
Keywords:
Note:
Dube, DC Indian Inst Technol,Dept Phys,New Delhi 110016,India Ecole Polytech Fed Lausanne,Lab Ceram,Mx Ecublens,Ch-1015 Lausanne,Switzerland Siemens Ag,Zfe T Mr2,D-81730 Munich,Germany
Wz554
Times Cited:8
Cited References Count:17
Laboratories:




 Record created 2006-08-21, last modified 2018-03-17