Within an ongoing project on controlled single-cell electroporation in microfluidic chips [1], a platform permitting accurate particle and fluid handling is being developed. This paper describes cell immersion as a practical demonstration of that platform. As an application, on-chip viability tests were conducted.
Titre
Microfluidic cell immersion on-chip cell viability test
Publié dans
MICRO TOTAL ANALYSIS SYSTEMS 2004, VOL 2
Série
ROYAL SOCIETY OF CHEMISTRY SPECIAL PUBLICATIONS
Numéro
297
Pages
270-272
Présenté à
8th International Conference on Miniaturized Systems for Chemistry and Life Sciences, Malmo, SWEDEN, SEP 26-30, 2004
Date
2005
Date de création de la notice
2005-09-13