This article investigates the effects of voids, joint geometry, and test conditions on the quasi-static Mode I fracture performance of thick adhesive Double Cantilever Beam (DCB) joints such as those prevailing in wind industry and shipbuilding. The specimens were made by glass fiber reinforced epoxy adherend and SikaPower®-830 epoxy adhesive in the cm thickness range. Side-grooved shape guided the crack propagation direction and assisted stable propagation, while lower cross-head displacement rates reduced the occurrence of unstable crack propagation and prevented crack deflection. Porosities, which are inevitable due to the high viscosity of the adhesive, led to unstable propagation and promoted crack path deviations. They could also decrease the apparent fracture energy release rate (SERR) since the crack surface is reduced. In conclusion, grooved DCB joints with low void content tested at low displacement rates showed stable crack propagation without significant crack path deviation. This method enables comparison with future adhesive formulations and the refinement of full-scale blade models.