  4. New capabilities of the incoherent Thomson scattering diagnostics in the TCV tokamak: divertor and real-time measurements
 
research article

New capabilities of the incoherent Thomson scattering diagnostics in the TCV tokamak: divertor and real-time measurements

Arnichand, H.
•
Andrebe, Y.  
•
Blanchard, P.  
Show more
September 1, 2019
Journal Of Instrumentation

This work reports developments of the incoherent TS diagnostic capabilities in the Tokamak a Configuration Variable (TCV). Their goals are to (i) diagnose the TCV divertor region, and (ii) provide Te and ne profiles of the plasma bulk in real-time. These two new TS diagnostic capabilities are implemented within the framework of a TCV upgrade that will insert baffles in the lower divertor region. 20 new TS spectrometers are being installed to access electron temperatures down to similar to 1 eV, for densities above similar to 1.5 x 10(19) m(-3) within the TCV divertor region. They will measure the Thomson light scattered along the vertical propagation path of the three legacy Nd:YAG lasers. The light at each of the 20 measurement plasma volumes is collected by three optical fibers with a laser-mapped spatial resolution of 5-6 mm each, providing a vertical spatial resolution of 15-18mm. Interference filters with central. Interference filters with central wavelengths from 1025 to 1061 nm and widths as low as similar to 2 nm are employed to obtain the spectroscopic resolution required at these low temperatures. The acquisition chain and analysis of the TS signal will be integrated into the TCV monitoring and control system to provide electron density and temperature profiles in real-time, at a sampling rate up to 60 Hz. The real time electron property profiles complement existing systems provided by the far-infrared interferometer and the soft X-ray diagnostics. The latter are restricted to provide integrated values of the electron density and temperature respectively, but at higher sampling rates (10 kHz and 20 kHz respectively). The whole diagnostic ensemble will be integrated into TCV's control system to improve the accuracy and robustness of real-time plasma profile and equilibrium estimation for control purposes.

  • Details
  • Metrics
Type
research article
DOI
10.1088/1748-0221/14/09/C09013
Web of Science ID

WOS:000486989800013

Author(s)
Arnichand, H.
Andrebe, Y.  
Blanchard, P.  
Antonioni, S.
Couturier, S.
Decker, J.
Duval, B. P.  
Felici, F.  
Galperti, C.
Isoz, P-F  
Show more
Date Issued

2019-09-01

Publisher

IOP PUBLISHING LTD

Published in
Journal Of Instrumentation
Volume

14

Article Number

C09013

Subjects

Instruments & Instrumentation

•

optics

•

plasma diagnostics - charged-particle spectroscopy

•

real-time monitoring

•

spectrometers

Note

3rd European Conference on Plasma Diagnostics (ECPD), May 06-10, 2019, Lisbon, PORTUGAL

Editorial or Peer reviewed

REVIEWED

Written at

EPFL

EPFL units
SPC  
Available on Infoscience
October 6, 2019
Use this identifier to reference this record
https://infoscience.epfl.ch/handle/20.500.14299/161855
Logo EPFL, École polytechnique fédérale de Lausanne
  • Contact
  • infoscience@epfl.ch

  • Follow us on Facebook
  • Follow us on Instagram
  • Follow us on LinkedIn
  • Follow us on X
  • Follow us on Youtube
AccessibilityLegal noticePrivacy policyCookie settingsEnd User AgreementGet helpFeedback

Infoscience is a service managed and provided by the Library and IT Services of EPFL. © EPFL, tous droits réservés