000261231 001__ 261231
000261231 005__ 20190617200540.0
000261231 0247_ $$a10.5075/epfl-thesis-9036$$2doi
000261231 037__ $$aTHESIS
000261231 041__ $$aeng
000261231 088__ $$a9036
000261231 245__ $$aPumps running as turbines for energy recovery in water supply systems
000261231 260__ $$aLausanne$$bEPFL$$c2018
000261231 269__ $$a2018
000261231 300__ $$a174
000261231 336__ $$aTheses
000261231 502__ $$aProf. Drazen Dujic (président) ; Prof. François Avellan, Prof. Dídia Isabel Cameira Covas (directeurs) ; Prof. Jürg Schiffmann, Dr Philippe Dupont, Dr Bernardo Silva (rapporteurs)
000261231 500__ $$aCo-supervision with: Instituto Superior Técnico (IST) da Universidade de Lisboa, Doutoramento em Engenharia Civil
000261231 520__ $$aPressurised water supply systems are infrastructures that offer a potential for energy recovery in locations where these systems operate with an excessive pressure. The integration of micro hydropower plants for energy recovery is a challenge, as these systems feature a significant daily discharge variation, which limits the domain of operation of the power plants.
Pumps running as turbines (PATs) are turbomachines suitable for this application, despite facing two issues. Firstly, PATs are characterised by a sharp efficiency decrease when operating far from the best operating point. Secondly, the characteristic curves of the turbine mode are not provided by pump manufacturers, which hinders the implementation of PAT power plants.
The present thesis is based on the experimental investigation of the variable speed operation of centrifugal pumps used as turbines aiming at optimising the energy recovered. A new methodology is developed, firstly, to estimate the performance of the turbine mode (flow rate, specific energy, power and efficiency) and, secondly, to model the variable speed hill chart performance of PATs. The research procedure includes the experimental investigation of the characteristic curves of the PATs, the experimental investigation of the unstable phenomena experienced by the PATs and, finally, the development of an empirical model for predicting the PATs performance.
Firstly, the variable speed operation of PATs is experimentally investigated. Data are collected for three centrifugal pumps with different unit specific speed values to characterise the characteristic curves of the turbine mode and of the extended operation in the generating mode. Measurements of the water temperature, the discharge, the pressure, the torque and the rotational speed are performed to determine the hydraulic and the mechanical performance of these PATs.
 Secondly, the pressure fluctuations developed during the part load and the full load operation of PATs are investigated. Data collected include the pressure measurements in the high and in the low pressure sections of the PAT and the high speed flow visualisation in the PAT draft tube. The spectral analysis of the pressure measurements and the image processing of the flow visualisation highlight the dynamics of a cavitation precessing vortex rope that develops in the PAT draft tube.
Thirdly, a new empirical model is developed to estimate the characteristic curve of PATs and to model the variable speed hill chart of the PAT. The methodology is based on the Hermite polynomial chaos expansion (PCE), which propagates the known characteristic curves obtained during the experimental tests, providing a surrogate function for predicting the characteristic curves of a given PAT, inside the range of unit specific speed values tested. The PCE is, afterwards, applied for modelling the variable speed hill chart of the PAT.
Obtained results provide an insight on the variable speed operation of PATs with respect to the turbine mode, the extended operation, the possibility of the development of pressure fluctuation instabilities and, finally, the modelling of the variable speed hill chart performance for a given PAT. The hill chart model is described by a continuous polynomial function, which can be used to optimise the design and the operation of PAT micro hydropower plants, aiming at maximising the energy recovered and at avoiding potential instabilities caused by the part load and the full load operation.
000261231 592__ $$b2018
000261231 6531_ $$aPumps running as turbines
000261231 6531_ $$avariable speed operation
000261231 6531_ $$awater supply systems
000261231 6531_ $$ahydropower
000261231 6531_ $$aperformance prediction
000261231 6531_ $$ahill chart modelling.
000261231 700__ $$0248463$$aGomes Borga Delgado, João Nuno$$g245541
000261231 720_2 $$aAvellan, François$$edir.$$g104417
000261231 720_2 $$aCameira Covas, Dídia Isabel$$edir.$$g209005
000261231 8564_ $$uhttps://infoscience.epfl.ch/record/261231/files/EPFL_TH9036.pdf$$s33168329
000261231 909C0 $$pLMH
000261231 909CO $$qGLOBAL_SET$$pthesis$$pSTI$$pDOI$$ooai:infoscience.epfl.ch:261231$$qthesis-public
000261231 918__ $$aSTI$$cIGM$$dEDEY
000261231 919__ $$aLMH
000261231 920__ $$a2018-11-23$$b2018
000261231 970__ $$a9036/THESES
000261231 973__ $$sPUBLISHED$$aEPFL
000261231 980__ $$aTHESIS