Reduction of the effects of spurious PLL tones on A/D converters

In a non-ideal PLL circuit, leakage of the reference signal into the control line produces spurious tones. When the distorted PLL signal is used in an analog-to-digital converter (ADC), it creates spurious tones in the sampled data as well. This paper analyzes this effect and proposes a solution to remove the leakage effects. The algorithm estimates the jitter errors from the spurious sidebands and provides a way to compensate the distorted sampled data in the digital domain.


Published in:
Proceedings of 2010 IEEE International Symposium on Circuits and Systems, 3985-3988
Presented at:
IEEE International Symposium on Circuits and Systems - ISCAS 2010, Paris, France, May 30 - June 2, 2010
Year:
2010
Publisher:
IEEE
Laboratories:




 Record created 2017-12-19, last modified 2018-03-17