Analysis of the part load helical vortex rope of a Francis turbine using on-board sensors

The cavitation helical vortex rope arising at Francis turbine partial load induces pressure fluctuations at the rope precession frequency, which can be decomposed into two components; the convective one and the synchronous one. The latter acts as an excitation source for the hydraulic system and is amplified in case of resonance. The present paper aims to highlight the impact of both components on the mechanical behaviour of the runner by performing on-board measurements. It is shown that the use of on-board pressure sensors enables to naturally separate the components of the pressure fluctuations. In addition, the synchronous component has little impact on the mechanical behaviour of the runner, even for the case in which hydro-acoustic resonance occurs.


Published in:
9th International Symposium on Cavitation (Cav2015), 656, 012061
Presented at:
9th International Symposium on Cavitation (CAV2015), Lausanne, Switzerland, December 6-10, 2015
Year:
2015
Publisher:
Bristol, Iop Publishing Ltd
ISSN:
1742-6588
Laboratories:




 Record created 2016-02-16, last modified 2018-03-17


Rate this document:

Rate this document:
1
2
3
 
(Not yet reviewed)