000198319 001__ 198319
000198319 005__ 20190228220013.0
000198319 0247_ $$2doi$$a10.1109/Tasc.2013.2284193
000198319 022__ $$a1051-8223
000198319 02470 $$2ISI$$a000332518500139
000198319 037__ $$aARTICLE
000198319 245__ $$aImpact of Cable Twist Pitch on T-cs-Degradation and AC Loss in Nb3Sn Conductors for ITER Central Solenoids
000198319 260__ $$bIeee-Inst Electrical Electronics Engineers Inc$$c2014$$aPiscataway
000198319 269__ $$a2014
000198319 300__ $$a5
000198319 336__ $$aJournal Articles
000198319 520__ $$aThe performance of tour Nb3Sn conductors for the ITER central solenoids was tested. The current sharing temperatures (T-cs) were measured over approximately 9000 electromagnetic cycles, including two or three thermal cycles between 4.2 K and room temperature. T-cs, increased and became almost constant through the cycling. The gradient of the electric field against the temperature gradually decreased against cycling. The degradations caused by the electromagnetic force of the short twist pitch conductors were smaller than that of the original twist pitch conductor. The ac losses of short twist pitch conductors were several times higher than that of original twist pitch conductor. The dents and the removals of the Cr plating on the strands, which were formed during cabling, decreased the electric resistance between strands, which may cause the observed high ac loss. Inspection of the cable showed neither a clear bias of cable in the cross-sectional surface nor distorted strands in the lateral face. The high rigidity of the short twist pitch cable could prevent these plastic deformations, caused by the Lorentz force.
000198319 6531_ $$aFusion reactors
000198319 6531_ $$amultifilamentary superconductors
000198319 6531_ $$asuperconducting coils
000198319 700__ $$uJapan Atom Energy Agcy, Ibaraki 3110193, Japan$$aNabara, Y.
000198319 700__ $$uJapan Atom Energy Agcy, Ibaraki 3110193, Japan$$aHemmi, T.
000198319 700__ $$uSH Copper Prod Co Ltd, Tsuchiura, Ibaraki 3000026, Japan$$aKajitani, H.
000198319 700__ $$uJapan Atom Energy Agcy, Ibaraki 3110193, Japan$$aOzeki, H.
000198319 700__ $$uJapan Atom Energy Agcy, Ibaraki 3110193, Japan$$aSuwa, T.
000198319 700__ $$uJapan Atom Energy Agcy, Ibaraki 3110193, Japan$$aIguchi, M.
000198319 700__ $$uJapan Atom Energy Agcy, Ibaraki 3110193, Japan$$aNunoya, Y.
000198319 700__ $$uJapan Atom Energy Agcy, Ibaraki 3110193, Japan$$aIsono, T.
000198319 700__ $$uJapan Atom Energy Agcy, Ibaraki 3110193, Japan$$aMatsui, K.
000198319 700__ $$uJapan Atom Energy Agcy, Ibaraki 3110193, Japan$$aKoizumi, N.
000198319 700__ $$uJapan Atom Energy Agcy, Ibaraki 3110193, Japan$$aTsutsumi, F.
000198319 700__ $$uJapan Atom Energy Agcy, Ibaraki 3110193, Japan$$aUno, Y.
000198319 700__ $$uJapan Atom Energy Agcy, Ibaraki 3110193, Japan$$aOshikiri, M.
000198319 700__ $$uJapan Atom Energy Agcy, Ibaraki 3110193, Japan$$aShibutani, K.
000198319 700__ $$uJapan Atom Energy Agcy, Ibaraki 3110193, Japan$$aTakahashi, Y.
000198319 700__ $$uJapan Atom Energy Agcy, Ibaraki 3110193, Japan$$aOkuno, K.
000198319 700__ $$uJapan Superconductor Technol Inc, Kitakyushu, Fukuoka 8000007, Japan$$aMurakami, Y.
000198319 700__ $$uJapan Superconductor Technol Inc, Kitakyushu, Fukuoka 8000007, Japan$$aMiyatake, T.
000198319 700__ $$uFurukawa Elect Corp Ltd, Nikko, Tochigi 3211493, Japan$$aSugimoto, M.
000198319 700__ $$uFurukawa Elect Corp Ltd, Nikko, Tochigi 3211493, Japan$$aTakagi, A.
000198319 700__ $$uSH Copper Prod Co Ltd, Tsuchiura, Ibaraki 3000026, Japan$$aNakada, Y.
000198319 700__ $$uSH Copper Prod Co Ltd, Tsuchiura, Ibaraki 3000026, Japan$$aMiyashita, K.
000198319 700__ $$aSedlak, K.
000198319 700__ $$aStepanov, B.
000198319 700__ $$aBruzzone, P.
000198319 773__ $$j24$$tIeee Transactions On Applied Superconductivity$$k3$$q4200705
000198319 909C0 $$pCRPP
000198319 909C0 $$0252028$$pSPC
000198319 909CO $$pSB$$particle$$ooai:infoscience.tind.io:198319
000198319 909C0 $$xU12272$$xU12268$$xU10558$$xU10635$$xU12266$$xU10636$$xU10137$$xU12270$$xU10557$$xU12273$$xU10559$$xU12271$$xU12269$$xU12267$$xU10136
000198319 917Z8 $$x112823
000198319 917Z8 $$x105317
000198319 937__ $$aEPFL-ARTICLE-198319
000198319 973__ $$rREVIEWED$$sPUBLISHED$$aEPFL
000198319 980__ $$aARTICLE