Laser‐Pumped Double‐Resonance Clock Using a Micro‐Fabricated Cell
2011
Abstract
In view of a novel miniature atomic clock with low power consumption, we investigate on the potential for a laserpumped double-resonance atomic clock based on a microfabricated Rb vapor cell. We obtain a clock short-term stability of 2x10-11 τ-1/2 and the stability stays below 1x10-11 up to τ = 104s, which demonstrates the feasibility of the approach.
Details
Title
Laser‐Pumped Double‐Resonance Clock Using a Micro‐Fabricated Cell
Author(s)
Pellaton, M. ; Pétremand, Y. ; Affolderbach, C. ; Mileti, G. ; de Rooij, N.
Published in
Proceedings of the IEEE International Frequency Control Symposium jointly with the European Frequency and Time Forum
Pages
604-606
Conference
IFCS‐EFTF, San Francisco, USA, May 1-5, 2011
Date
2011
Laboratories
SAMLAB
Record Appears in
Scientific production and competences > STI - School of Engineering > STI Archives > SAMLAB - Sensors, Actuators and Microsystems Laboratory
Conference Papers
Work produced at EPFL
Published
Conference Papers
Work produced at EPFL
Published
Record creation date
2011-11-21