Corona Discharge in Microwave Devices: A Comparison of Ionization Rate Models

In this paper we compare the predicted Corona breakdown power threshold obtained by different ionization rate models for an infinite parallel-plate waveguide. We point out the lack of a unanimous model of the ionization rate for RF fields and study the differences in the current models.


Published in:
IEEE Microwave Review, ISSN 14505835, 16, 1, 41-46
Year:
2010
Keywords:
Note:
Invited
Laboratories:




 Record created 2010-11-25, last modified 2018-01-28