Abstract

The PFCI is a single-layer solenoid wound from a 45 m long ITER-type NbTi dual-channel cable-in-conduit conductor, designed to be representative of the one currently proposed for the ITER PF1&6 coils. The PFCI, installed in the bore of the ITER central solenoid model coil (CSMC) at JAEA Naka, Japan, and well instrumented from both the thermal hydraulic and the electromagnetic points of view, has been successfully tested in June-August 2008. The test concentrated on DC performance (current sharing temperature and critical current measurements) and AC loss measurements. The results of the analysis of those measurements are reported in the paper, with particular attention to the comparison with the PFCI short sample, which was previously tested in the SULTAN facility. The evolution of the DC performance of the CSMC is also discussed.