TEM cell testing of cable noise reduction techniques from 2 MHz to 200 MHz - Part 2
This paper presents empirical results of cable noise reduction techniques as demonstrated in a TEM cell operating with radiated fields from 2 - 200 MHz. It is the second part of a two-paper series. The first paper discussed cable types and shield connections. In this second paper, the effects of load and source resistances and chassis connections are examined. For each topic, well established theories are compared to data from a real-world physical system. Finally, recommendations for minimizing cable susceptibility (and thus cable emissions) are presented.
2008 Asia-Pacific Part 2 Arthur Bradley Final.pdf
openaccess
167.71 KB
Adobe PDF
a263c92c54981fd092fa17d63121bc57