Modeling of Multi-winding Phase Shifting Transformers : Application to DC and Multi-level VSI Supplies.

This paper deals with the modeling of multi-winding transformers. Based on the real example of a railway DC - supply, a modeling methodology is presented as the original part of the paper. Afterwards two application examples of multi-winding phase shifting transformers (18 and 24 pulse) are described, these applications have been simulated using the SIMSEN simulation software package [1,2]. Harmonics analysis of simulation results (elimination of low order harmonics 5, 7, 11, 13) has validated the proposed methodology.