Abstract

Due to their poor sizing, grid-connected photovoltaic systems often underexploit the capacity of the static inverter resulting in reduced efficiency and an increase in the cost of energy. The simulations performed in a previous phase of the project showed that higher profitability was attained with the nominal photovoltaic field sized between 40 and 80% (depending on conditions) above the nominal power of the static inverter.