DC and transient current distribution analysis from self-field measurements on ITER PFIS conductor

Current reconstruction in cable-in-conduit conductors (CICC) cables is a crucial issue to determine cables performance in working conditions, and must be performed using inverse problem approaches as direct measurement is not feasible. The current distribution has been studied for the ITER Poloidal Field Insert Sample (PFIS) conductor using annular arrays of Hall probes placed in three different locations along the sample during the test campaign at the SULTAN facility. The measurement apparatus is also described in the paper, together with the approach to current reconstruction. (c) 2005 Elsevier B.V. All rights reserved.


Published in:
Fusion Engineering and Design, 75-9, 11-15
Year:
2005
ISSN:
0920-3796
ISBN:
0920-3796
Keywords:
Other identifiers:
Laboratories:
SPC
CRPP




 Record created 2008-04-16, last modified 2018-01-28