000120073 245__ $$aImpact of impressed current unbalance on n-index
000120073 260__ $$c2004
000120073 269__ $$a2004
000120073 336__ $$aJournal Articles
000120073 500__ $$aSp. Iss. SI
000120073 520__ $$aThree subsize NbTi cable-in-conduit conductors have been tested in SULTAN test facility. The conductors are identical in the cable layout but they are different in transverse resistance: either SnAg strand coating without wraps, or Ni strand coating without wraps or Ni strand coating with the stainless steel wrapping of the last but one cable stage. Variation of initial current unbalance at the termination is provided by the demountable conductor termination. The effect of the transverse resistance on ability to redistribute the artificially unbalanced current (variation of the V-I characteristics and their n-index) has been investigated for various extents of the current unbalance: either 100%, or 75% or 50% of the strands are connected to the termination.
000120073 700__ $$0240062$$g134508$$aStepanov, B.
000120073 700__ $$aAnghel, A.
000120073 700__ $$g113537$$aBruzzone, P.$$0240063
000120073 700__ $$aVogel, M.
000120073 773__ $$j14$$tIeee Transactions on Applied Superconductivity$$k2$$q1495-1498
000120073 909CO $$pSB$$particle$$ooai:infoscience.tind.io:120073
000120073 909C0 $$pCRPP
000120073 909C0 $$0252028$$pSPC$$xU12272$$xU12268$$xU10558$$xU10635$$xU12266$$xU10636$$xU10137$$xU12270$$xU10557$$xU12273$$xU10559$$xU12271$$xU12269$$xU12267$$xU10136
000120073 937__ $$aCRPP-ARTICLE-2004-018
000120073 973__ $$rREVIEWED$$sPUBLISHED$$aEPFL
000120073 980__ $$aARTICLE